EX signal isolating converter, Ex-output: U, I, R,ϑ, Safe-output: 4-20mA/ relay, 1-channelACT20X-HUI-SAO-S
Weidmuller 8965490000 is now available new, surplus, and used from Williams Automation.
If you need a specific firmware or series relating to this item, please call or email us with your request.
We can also provide specifications and/or a data sheet for this item upon request. Please call or email us if you require one.
Please note we offer UPS Next Day Air shipping for all orders. Please be sure to select next day shipping at checkout, and we will provide same-day shipment.
Call (803) 761-7027 if you have any questions about availability, or email us at sales@williamsautomation.com.
Alarm Output
- Alarm function
- No supply voltage, Device error
- Continuous current
- ≤ 0.5 A AC / 0.3 A DC (safe zone), ≤ 0,5 A AC / 1 A DC (zone 2)
- Nominal switching voltage
- ≤ 125 V AC / 110 V DC (safe area)≤ 32 V AC / 32 V DC (zone 2)
- Power rating
- ≤ 62.5 VA / 32 W (safe area)≤ 16 VA / 32 W (Zone 2)
- Type
- Relay, 1 NC (voltage-free)
Approvals
- ROHS
- Conform
- UL File Number Search
- E337701
Classifications
- eClass 10.0
- 27-21-01-20
- eClass 9.0
- 27-21-01-20
- eClass 9.1
- 27-21-01-20
- ETIM 6.0
- EC002653
- ETIM 7.0
- EC002653
- UNSPSC
- 30-21-18-01
Connection Data
- Clamping range, max.
- 2.5 mm²
- Clamping range, min.
- 0.25 mm²
- Clamping range, rated connection
- 2.5 mm²
- Tightening torque, max.
- 0.6 Nm
- Tightening torque, min.
- 0.4 Nm
- Type of connection
- Screw connection
- Wire connection cross section AWG, max.
- AWG 12
- Wire connection cross section AWG, min.
- AWG 26
Data For Ex Applications (Atex)
- Current I
- 18.4 mA
- Installation location
- Device installed in safe area, zone 2
- Marking
- II (1) G [Ex ia Ga] IIC/IIB/IIA, I (M1) [Ex ia Ma] I, II (1) G [Ex ia Ga] IIC, II (1) D [Ex ia Da] IIIC
- Power P
- 40 mW
- Voltage U
- 8.7 V DC
Digital Output
- Continuous current
- ≤ 2 A AC/DC (safe area, Zone 2 area)
- Function
- Configurable switching thresholds, Sensor error, Window function
- Nominal switching voltage
- ≤ 250 V AC / 30 V DC (safe area)≤ 32 V AC / 32 V DC (zone 2)
- Power rating
- ≤ 500 VA / 60 W (safe area)≤ 16 VA / 32 W (Zone 2)
- Type
- Relay, 1 NO / NC contact
Dimensions And Weights
- Depth
- 113.6 mm
- Depth (inches)
- 4.472 inch
- Height
- 119.2 mm
- Height (inches)
- 4.693 inch
- Net weight
- 202 g
- Width
- 22.5 mm
- Width (inches)
- 0.886 inch
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
General Specifications
- Configuration
- With FDT/DTM software
- Humidity
- 0...95 % (no condensation)
- Power consumption
- ≤ 2.1 W
- Protection degree
- IP20
- Type of connection
- Screw connection
- Voltage supply
- 19.2…31.2 V DC
Input Ex
- Input current
- 0...20 mA, 4...20 mA
- Input resistance
- configurable, 0…10 kΩ
- Input resistance, current
- 20 Ω + PTC 50 Ω
- Input resistance, voltage
- > 10 MΩ @ 600 mV, 2 MΩ @ 28 V
- Input voltage
- configurable, 0…1 V DC, 0,2…1 V DC, 1…5 V DC, 0...(5)10 V, 2…10 V DC
- Line resistance in measuring circuit
- ≤ 50 Ω
- Potentiometer
- 10 Ω…10 kΩ
- Sensor
- 2-/3-/4-wire, RTD: PT10, PT20, PT50, PT100, PT250, PT300, PT400, PT500, PT1000, Ni50, Ni100, Ni120, Ni1000, Thermocouples: B, E, J, K, N, R, S, T ; in compliance with IEC 60584-1 and L, U in compliance with DIN43710, Potentiometer, Resistance: 0 - 12 kΩ
- Temperature input range
- Adjustable from -200...+800°C
- Type
- intrinsically safe circuit, active (as current source) or passive (as current sink)
Insulation Coordination
- EMC standards
- DIN EN 61326, NE 21
- Insulation voltage
- 2.6 kV (input / output)
- Pollution severity
- 2
- Rated voltage
- 300 V
Output
- Influence of load resistance
- ≤ 0.01% of span / 100 Ω
- load impedance current
- ≤ 600 Ω
- Output current
- 0…23 mA, configurable: 0…20 / 4…20 / 20…0 / 20…4 mA, configurable downscale (3.5 mA) ⁄ upscale (23 mA) @ error
- Output signal limit
- 3.8…20.5 mA / 0…20.5 mA (dependent on range)
- Type
- active (as current source) or passive (as current sink)
Probability Of Failure
- MTBF
- 74 Years
- SIL PAPER
- SIL certificate
Product Information
- Product information
- Weidmüller provides an extended guarantee period of 36 months for this device.
Rated Data Ul
- UL certificate
- E337701.pdf
Ratings Iecex/Atex/Cul
- ATEX certificate
- 10ATEX0071X.pdf
- Certificate No. (ATEX)
- KEMA10ATEX0071X
- Certificate no. (cULus)
- E337701
- Certificate No. (IECEX)
- IECEXKEM10.0034X
- IEC Ex certificate
- IECEx certification
Safety-Related Basic Specifications
- Demand mode
- High
- Demand rate
- 3,000 s
- Demand response time
- Signal input: < 0.5 s (opto output), Temperature input: < 1.1 s (opto output)
- Description of the "safe state"
- analogue Output ≤ 3.6 mA or output ≥ 21 mA, de-energized (relay output)
- Device type
- B
- Diagnostic test interval
- 30 s
- Hardware fault tolerance (HFT)
- 0
- Mean Time To Repair (MTTR)
- 24 h
- Probability of outage PFH
- 4.33 x 10-8 h-1
- Relay lifetime
- 100000 times
- Safe Failure Fraction (SFF)
- 93 %
- Safety category
- SIL 2
- T
- 4 Years
- Total failure rate for dangerous detected failures (λ
- 352 FIT
- Total failure rate for dangerous undetected failures (λ
- 43 FIT
- Total failure rate for safe detected failures (λ
- 0 FIT
- Total failure rate for safe undetected failures (λ
- 278 FIT
Safety-Related Specifications Low Demand Mode
- Average Probability of Failure on Demand (PFD
- 2.82 x 10-4 (Tproof = 1 year), 4.63 x 10-4 (Tproof = 2 years), 1.00 x 10-3 (Tproof = 5 years), additional data in the safety manual
Temperatures
- Humidity
- 0...95 % (no condensation)
- Operating temperature
- -20 °C...60 °C
- Operating temperature, max.
- 60 °C
- Operating temperature, min.
- -20 °C
- Storage temperature
- -20 °C...85 °C
- Storage temperature, max.
- 85 °C
- Storage temperature, min.
- -20 °C
Tender Specification Sheets
- Long specification
- Ex universal measurement isolating transformer and trip amplifier for RTD-/ TC temperature and DC-current-/ voltage signals1-channel measurement isolating transformer and trip amplifier in 22.5 mm width with external power supply, for capturing and isolating RTD- / TC sensors, resistors , potentiometers and DC current signals 0(4)...20 mA and voltages 0...12 V from Ex zones 0,1,2. Sensors can be supplied via the 0...20 mA current loop. The output can be operated as either an active 0(4)...20 mA signal or as a passive 4...20 mA current loop. A relay contact (NO) is available on the output side for limit value monitoring. Status/error messages are issued via a relay contact (NO). The component can be configured using standard FDT/DTM software. Add-on housing for TS35 rail mounting Dimensions: L/W/H 119.2/ 22.5/ 113.6Screw connection/ Nominal cross-section 2.5 mm2Protection degree: IP 20 Input RTD: PT100, PT500, PT1000, Ni50, Ni100, Ni120, Ni1000 Resistance 0...10 kOHm / Potentiometer 10 Ohm... 10 kOhm TC- Type: B, E, J, K, N, R, S, T, U, L 0(4)...20 mA 0...12 V/ 2...10 V Sensor supply 28...16.5 VDC / 0...20 mA Output active 0(4)...20 mA / 20..0 mA configurable passive 4...20 mA current loop 3.5...26 V DCLoad < 600 Ohm Alarm output relay 1 NO contact 250 V AC / 30 V DC @ 2A safe zone 32 V AC @ 0.5 A/ 32 VDC @ 1 A Zone 2 Accuracy < 0,1 % v.E Temperature coefficient < 0,01% v.E./°C (Tu) Alarm output relay 1 NO contact 250 V AC / 30 V DC @ 2A safe zone 32 V AC @ 0.5 A/ 32 VDC @ 1 A Zone 2Auxiliary power 19...31.2 V DC Power loss approx. 3.5 W Ambient temperature range -20 °C...+60 °C Secure isolation EN 61010, 3-way isolation up to 2.6 kV AC/DC of all circuits against each otherWorking voltage 300 V AC/DC at overvoltage category II and pollution degree 2 Approvals cULus, ATEX IECEX, FM ATEX marking II 3 G ExnA nC IIC T4 ATEX characteristic data U0 = 8.7 V DC I0 = 18.4 mA DC P0 = 40 mW Type ACT20X-HUI-SAO-S
- Short specification
- Ex universal measurement isolating transformer and trip amplifier for RTD-/ TC temperature and DC-current-/ voltage signals1-channel measurement isolating transformer and trip amplifier in 22.5 mm width with external power supply, for capturing and isolating RTD- / TC sensors, resistors , potentiometers and DC current signals 0(4)...20 mA and voltages 0...12 V from Ex zones 0,1,2. Sensors can be supplied via the 0...20 mA current loop. The output can be operated in the safe zone as either an active 0(4)...20 mA signal or a passive 4...20 mA current loop. A relay contact (NO) is available for limit-value monitoring on the output side. Status and error messages are issued via a relay contact (NO). The component can be configured using standard FDT/DTM software.
Reviews
What our customers say
Rating they have quick great service and quick shipping!! would recommend doing business over and over!!
Great price and speedy delivery. I am certain, based on my first statement that if needed, customer support will be excellent
Great customer service, fast shipping. Nice to deal with a company that shows they care about their customers.
I got the part and it was exactly what i needed to get my dust collector up and running again! It was also at very reasonable price. Thanks!
Another great purchase from Williams Automation. You will have peace of mind knowing your getting authentic parts from Williams Automation. Very easy to work with and great customer service. Plus you get at a competitive price and not three times what it should be.
Exceptional customer service! They had the elusive part I required readily available and responded promptly to all my emails.
Great customer service. Had the hard to find parts I needed in stock. All emails answered promptly.
Had what I needed in stock, shipped fast and arrived within the time frame indicated. It was packaged securely.
Perfect purchase! The whole process was great, including the packaging and shipping. Finally a company who cares!
Great service and Best prices ! Very organized company and helpful too. Will definitely buy again