Description
Weidmuller 8965480000 is now available from Williams Automation.
If you need a specific firmware version or series for this item, please call or email us with your request. We can also provide specifications and/or a data sheet for this item upon request. Please call or email us if you need one.
We offer Overnight shipping for most items listed on our website. Please get in touch with us to confirm whether the product can ship overnight on the day of your order. Cutoff times are typically 2-3 PM EST. Lead times can range from 1 to 4 business days.
Call (803) 761-7027 if you have any questions about availability, or email us at sales@williamsautomation.com.
Alarm Output
- Alarm function
- Line interruption at the input, Short circuit at input, No supply voltage, Device error
- Continuous current
- ≤ 0.5 A AC / 0.3 A DC (safe zone), ≤ 0,5 A AC / 1 A DC (zone 2)
- Nominal switching voltage
- ≤ 125 V AC / 110 V DC (safe area)≤ 32 V AC / 32 V DC (zone 2)
- Power rating
- ≤ 62.5 VA / 32 W (safe area)≤ 16 VA / 32 W (Zone 2)
- Type
- Relay, 1 NC (voltage-free)
Approvals
- ROHS
- Conform
- UL File Number Search
- E337701
Classifications
- eClass 10.0
- 27-21-01-29
- eClass 9.0
- 27-21-01-29
- eClass 9.1
- 27-21-01-29
- ETIM 6.0
- EC002919
- ETIM 7.0
- EC002919
- UNSPSC
- 30-21-18-01
Connection Data
- Clamping range, max.
- 2.5 mm²
- Clamping range, min.
- 0.25 mm²
- Clamping range, rated connection
- 2.5 mm²
- Tightening torque, max.
- 0.6 Nm
- Tightening torque, min.
- 0.4 Nm
- Type of connection
- Screw connection
- Wire connection cross section AWG, max.
- AWG 12
- Wire connection cross section AWG, min.
- AWG 26
Data For Ex Applications (Atex)
- Current I
- 18.4 mA
- Installation location
- Device installed in safe area, zone 2
- Marking
- II (1) G [Ex ia Ga] IIC/IIB/IIA, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I
- Power P
- 40 mW
- Voltage U
- 8.7 V DC
Dimensions And Weights
- Depth
- 113.6 mm
- Depth (inches)
- 4.472 inch
- Height
- 119.2 mm
- Height (inches)
- 4.693 inch
- Net weight
- 180 g
- Width
- 22.5 mm
- Width (inches)
- 0.886 inch
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
General Specifications
- Configuration
- With FDT/DTM software
- Humidity
- 0...95 % (no condensation)
- Power consumption
- ≤ 1.4 W
- Protection degree
- IP20
- Step response time
- ≤ 400 ms (with current), ≤ 1 s (with temperature)
- Type of connection
- Screw connection
- Voltage supply
- 19.2…31.2 V DC
Input Ex
- Input current
- 0...20 mA, 4…20mA
- Input resistance, current
- 20 Ω + PTC 50 Ω
- Line resistance in measuring circuit
- ≤ 50 Ω
- Sensor
- RTD: PT10, PT20, PT50, PT100, PT250, PT300, PT400, PT500, PT1000, Ni50, Ni100, Ni120, Ni1000, Thermocouples: B, E, J, K, N, R, S, T ; in compliance with IEC 60584-1 and L, U in compliance with DIN43710
- Temperature input range
- Configurable
- Type
- intrinsically safe circuit, RTD, TC, DC (mA)
Insulation Coordination
- EMC standards
- DIN EN 61326, NE 21
- Insulation voltage
- 2.6 kV (input / output)
- Rated voltage
- 300 V
Output
- Influence of load resistance
- ≤ 0.01% of span / 100 Ω
- load impedance current
- ≤ 600 Ω
- Output current
- 0…23 mA, configurable: 0…20 / 4…20 / 20…0 / 20…4 mA, configurable downscale (3.5 mA) ⁄ upscale (23 mA) @ error
- Output signal limit
- 3.8…20.5 mA / 0…20.5 mA (dependent on range)
- Type
- active (as current source) or passive (as current sink)
Probability Of Failure
- MTBF
- 111 Years
- SIL in compliance with IEC 61508
- 2
- SIL PAPER
- SIL certificate
Product Information
- Product information
- Weidmüller provides an extended guarantee period of 36 months for this device.
Rated Data Ul
- UL certificate
- E337701.pdf
Ratings Iecex/Atex/Cul
- ATEX certificate
- 10ATEX0020X.pdf
- Certificate No. (ATEX)
- KEMA10ATEX0020X
- Certificate no. (cULus)
- E337701
- Certificate No. (IECEX)
- IECEXKEM09.0092X
- IEC Ex certificate
- IECEx certification
Safety-Related Basic Specifications
- Demand mode
- High
- Demand rate
- 3,000 s
- Demand response time
- Signal input: < 0.5 s (opto output), Temperature input: < 1.1 s (opto output)
- Description of the "safe state"
- analogue Output ≤ 3.6 mA or output ≥ 21 mA
- Device type
- B
- Diagnostic test interval
- 30 s
- Hardware fault tolerance (HFT)
- 0
- Mean Time To Repair (MTTR)
- 24 h
- Probability of outage PFH
- 6.1 x 10-8 h-1
- Safe Failure Fraction (SFF)
- 90 %
- Safety category
- SIL 2
- T
- 3 Years
- Total failure rate for dangerous detected failures (λ
- 367 FIT
- Total failure rate for dangerous undetected failures (λ
- 61 FIT
- Total failure rate for safe detected failures (λ
- 0 FIT
- Total failure rate for safe undetected failures (λ
- 234 FIT
Safety-Related Specifications Low Demand Mode
- Average Probability of Failure on Demand (PFD
- 3.96 x 10-4 (Tproof = 1 year), 6.5 x 10-4 (Tproof = 2 years), 1.41 x 10-4 (Tproof = 5 years)
Temperatures
- Humidity
- 0...95 % (no condensation)
- Operating temperature
- -20 °C...60 °C
- Operating temperature, max.
- 60 °C
- Operating temperature, min.
- -20 °C
- Storage temperature
- -20 °C...85 °C
- Storage temperature, max.
- 85 °C
- Storage temperature, min.
- -20 °C
Tender Specification Sheets
- Long specification
- Ex temperature transducer for RTD-/ TC temperature signals and DC current signals, 2-channel2-channel temperature transducer in 22.5 mm width with external power supply, for capturing and isolating RTD- / TC sensors and DC current signals 0(4)...20 mA from the Ex Zones 0, 1, 2. The outputs can be operated as either an active 0(4)...20 mA signal or as a passive 4...20 mA current loop. Status and error messages are available via a relay contact (NO). The component can be configured using standard FDT/DTM software. Add-on housing for TS35 rail mounting Dimensions: L/W/H 119.2/ 22.5/ 113.6Screw connection/ Nominal cross-section 2.5 mm2Protection degree: IP 20 Input / channel RTD: PT100, PT500, PT1000, Ni100, Ni120, Ni1000 TC- Type: B, E, J, K, N, R, S, T, U, L 0(4)...20 mA Output / channel active 0(4)...20 mA / 20..4 mA configurable passive 4...20 mA current loop 3.5...26 V DC Load / channel < 600 Ohm Accuracy < 0,1 % v.E. Temperature coefficient < 0,01% v.E./°C (Tu) Alarm output relay 1 NO contact 250 V AC / 30 V DC @ 2A safe zone 32 V AC @ 0.5 A/ 32 VDC @ 1 A Zone 2Auxiliary power 19...31.2 V DC Power loss approx. 3 W Ambient temperature range -20 °C...+60 °C Secure isolation EN 61010, 3-way isolation up to 2.6 kV AC/DC of all circuits against each otherWorking voltage 300 V AC/DC at overvoltage category II and pollution degree 2 Approvals cULus, ATEX IECEX, FM ATEX marking II 3 G ExnA nC IIC T4 ATEX characteristic data U0 = 8.7 V DC I0 = 18.4 mA DC P0 = 40 mW Type ACT20X-2HTI-2SAO-S
- Short specification
- Ex- temperature transducer for RTD-/ TC temperature signals and DC current signals, 2-channel2-channel temperature transducer in 22.5 mm width with external power supply,for capturing and isolating RTD/TC sensor and DC current signals (0(4)...20 mA) from Ex zones 0,1,2. The outputs can be operated in the safe zone either as an active signal (0(4)...20 mA) or as a passive 4...20 mA current loop. Status and error messages are available via a relay contact (NO).The component can be configured using standard FDT/DTM software.
Reviews