EX signal isolating converter, Safe-input: 4-20mA, Ex output: 4 - 20 mA, 1-channelACT20X-SAI-HAO-S
Weidmuller 8965450000 is now available new, surplus, and used from Williams Automation.
If you need a specific firmware or series relating to this item, please call or email us with your request.
We can also provide specifications and/or a data sheet for this item upon request. Please call or email us if you require one.
Please note we offer UPS Next Day Air shipping for all orders. Please be sure to select next day shipping at checkout, and we will provide same-day shipment.
Call (803) 761-7027 if you have any questions about availability, or email us at sales@williamsautomation.com.
Alarm Output
- Alarm function
- Signal limit exceeded, Line interruption at the input, No supply voltage, Device error
- Continuous current
- ≤ 0,5 A AC / 1 A DC (zone 2)
- Hysteresis
- 0.1 mA (switching threshold)
- Nominal switching voltage
- ≤ 125 V AC / 110 V DC (safe area)≤ 32 V AC / 32 V DC (zone 2)
- Power rating
- ≤ 62.5 VA / 32 W (safe area)≤ 16 VA / 32 W (Zone 2)
- Switching thresholds
- 0…29.9 mA (programmable)
- Type
- Relay, 1 NO (voltage-free)
Approvals
- ROHS
- Conform
- UL File Number Search
- E337701
Classifications
- eClass 10.0
- 27-21-01-23
- eClass 9.0
- 27-21-01-23
- eClass 9.1
- 27-21-01-23
- ETIM 6.0
- EC002475
- ETIM 7.0
- EC002475
- UNSPSC
- 30-21-18-01
Connection Data
- Clamping range, max.
- 2.5 mm²
- Clamping range, min.
- 0.25 mm²
- Clamping range, rated connection
- 2.5 mm²
- Tightening torque, max.
- 0.6 Nm
- Tightening torque, min.
- 0.4 Nm
- Type of connection
- Screw connection
- Wire connection cross section AWG, max.
- AWG 12
- Wire connection cross section AWG, min.
- AWG 26
Data For Ex Applications (Atex)
- Current I
- 93 mA
- Installation location
- Device installed in safe area, zone 2
- Marking
- II (1) G [Ex ia Ga] IIC/IIB/IIA, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I
- Power P
- < 650 mW
- Voltage U
- 28 V DC
Dimensions And Weights
- Depth
- 113.6 mm
- Depth (inches)
- 4.472 inch
- Height
- 119.2 mm
- Height (inches)
- 4.693 inch
- Net weight
- 189 g
- Width
- 22.5 mm
- Width (inches)
- 0.886 inch
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
General Specifications
- Accuracy
- < 0.1% span
- Configuration
- With FDT/DTM software
- Humidity
- 0...95 % (no condensation)
- Power consumption
- ≤ 1.0 W
- Protection degree
- IP20
- Step response time
- ≤ 5 ms
- Temperature coefficient
- < 0.01% of span/°C (TU)
- Type of connection
- Screw connection
- Voltage supply
- 19.2…31.2 V DC
Input
- Input current
- 4…20mA
- Input frequency
- 0,5…2,5 kHz @ 3,5…23 mA bi-directional HART® signal
- Voltage drop
- < 2 V
Input Ex
- Input current
- 4…20mA
- Input frequency
- 0,5…2,5 kHz @ 3,5…23 mA bi-directional HART® signal
- Output signal in case of wire break
- < 1 mA
- Voltage drop
- < 2 V
- Voltage drop not powered
- < 6 V
- Voltage drop powered
- < 2 V
Insulation Coordination
- EMC standards
- DIN EN 61326, NE 21
- Insulation voltage
- 2.6 kV (input / output)
- Rated voltage
- 300 V
Output
- 2-wire supply
- > 14.5 V @ 20 mA
- Cut-off frequency (-3 dB)
- 0.5…2.5 kHz @ 3.5…23 mA bi-directional HART® signal
- Influence of load resistance
- ≤ 0.01% of span / 100 Ω
- load impedance current
- ≤ 725 Ω
- Output current
- 4…20 mA (max. 23 mA)
- Output signal limit
- < 28 mA
- Residual ripple (current loop)
- < 7.5 mVeff
- Type
- intrinsically safe circuit
Probability Of Failure
- MTBF
- 135 Years
- SIL PAPER
- SIL certificate
Product Information
- Product information
- Weidmüller provides an extended guarantee period of 36 months for this device.
Rated Data Ul
- UL certificate
- E337701.pdf
Ratings Iecex/Atex/Cul
- ATEX certificate
- 11ATEX0164X.pdf
- Certificate no. (cULus)
- E337701
- IEC Ex certificate
- IECEx certification
Safety-Related Basic Specifications
- Demand mode
- High
- Description of the "safe state"
- analogue Output ≤ 3.6 mA or output ≥ 21 mA
- Device type
- A
- Hardware fault tolerance (HFT)
- 0
- Mean Time To Repair (MTTR)
- 24 h
- Probability of outage PFH
- 4.8 x 10-8 h-1
- Safe Failure Fraction (SFF)
- 85 %
- Safety category
- SIL 2
- T
- 5 Years
- Total failure rate for dangerous detected failures (λ
- 127 FIT
- Total failure rate for dangerous undetected failures (λ
- 48 FIT
- Total failure rate for safe detected failures (λ
- 0 FIT
- Total failure rate for safe undetected failures (λ
- 164 FIT
Safety-Related Specifications Low Demand Mode
- Average Probability of Failure on Demand (PFD
- 2.29 x 10-4 (Tproof = 1 year), 4.37 x 10-4 (Tproof = 2 years), 1.06 x 10-4 (Tproof = 5 year)
Temperatures
- Humidity
- 0...95 % (no condensation)
- Operating temperature
- -20 °C...60 °C
- Operating temperature, max.
- 60 °C
- Operating temperature, min.
- -20 °C
- Storage temperature
- -20 °C...85 °C
- Storage temperature, max.
- 85 °C
- Storage temperature, min.
- -20 °C
Tender Specification Sheets
- Long specification
- Ex output isolation amplifier for standard DC current signals, HART transparent1-channel output isolation amplifier in 22.5 mm width with external power supply,for transmitting and isolating standard signals 4 to 20 mA from the safe zone to Ex zones 0,1,2. Status-/ error messages are available via a relay contact (NO).The component can be configured using standard FDT/DTM software.Add-on housing for TS35 rail mountingDimensions: L/W/H 119.2/ 22.5/ 113.6Screw connection/ Nominal cross-section 2.5 mm2Protection degree: IP 20 Input 4...20 mA Output 4...20 mALoad < 600 OhmAccuracy < 0,1 % v.ETemperature coefficient < 0,01% v.E./°C (Tu)Alarm output relay 1 NO contact 250 V AC / 30 V DC @ 2A safe zone 32 V AC @ 0.5 A/ 32 VDC @ 1 A Zone 2Auxiliary power 19...31.2 V DCPower loss approx. 1.8 WAmbient temperature range -20 °C...+60 °CSecure isolation EN 61010, 3-way isolation up to 2.6 kV AC/DC of all circuits against each otherWorking voltage 300 V AC/DC at overvoltage category II and pollution degree 2Approvals cULus, ATEX IECEX, FMATEX marking II 3 G ExnA nC IIC T4ATEX characteristic data U0 = 28 V DC I0 = 93 mA DC P0 = 650 mWType ACT20X-SAI-HAO-S
- Short specification
- Ex output isolation amplifier for standard DC current signals, HART transparent1-channel output isolation amplifier in 22.5 mm width with external power supply,for transmitting and isolating standard signals 4 to 20 mA from the safe zone to Ex zones 0,1,2. Status-/ error messages are available via a relay contact (NO).The component can be configured using standard FDT/DTM software.
Reviews
What our customers say
Rating they have quick great service and quick shipping!! would recommend doing business over and over!!
Great price and speedy delivery. I am certain, based on my first statement that if needed, customer support will be excellent
Great customer service, fast shipping. Nice to deal with a company that shows they care about their customers.
I got the part and it was exactly what i needed to get my dust collector up and running again! It was also at very reasonable price. Thanks!
Another great purchase from Williams Automation. You will have peace of mind knowing your getting authentic parts from Williams Automation. Very easy to work with and great customer service. Plus you get at a competitive price and not three times what it should be.
Exceptional customer service! They had the elusive part I required readily available and responded promptly to all my emails.
Great customer service. Had the hard to find parts I needed in stock. All emails answered promptly.
Had what I needed in stock, shipped fast and arrived within the time frame indicated. It was packaged securely.
Perfect purchase! The whole process was great, including the packaging and shipping. Finally a company who cares!
Great service and Best prices ! Very organized company and helpful too. Will definitely buy again