Approvals
- Approvals
- CE, CSAEX, EAC, FUSAFETY, IECEXDEK, KEMAATEX
- ROHS
- Conform
Classifications
- eClass 10.0
- 27-13-08-07
- eClass 9.0
- 27-13-08-07
- eClass 9.1
- 27-13-08-07
- ETIM 6.0
- EC000943
- ETIM 7.0
- EC000943
- UNSPSC
- 30-21-19-21
Connection Data
- Type of connection
- Pluggable in VSPC BASE
Csa Protection Data
- Gas group C
- IIB
- Gas group D
- IIA
- Gas groups A, B
- IIC
- Input voltage, max. U
- 26 V
- Internal capacity, max. C
- 4 nF
- Internal inductance, max. L
- 0 µH
Dimensions And Weights
- Depth
- 69 mm
- Depth (inches)
- 2.717 inch
- Height
- 90 mm
- Height (inches)
- 3.543 inch
- Net weight
- 47 g
- Width
- 17.8 mm
- Width (inches)
- 0.701 inch
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
Further Details Of Approvals
- GOST certificate
- GOST-Zertifikat
General Data
- Colour
- Light Blue
- Design
- Terminal, miscellaneous
- Optical function display
- No
- protected binary signals
- 2
- Protection degree
- IP20
- Segment
- Measurement - Monitoring - Setting
- UL 94 flammability rating
- V-0
- Version
- without warning function / function indicator
Insulation Coordination Acc. To En 50178
- Pollution severity
- 2
- Surge voltage category
- III
Probability Of Failure
- MTTF
- 2,665 Years
- PFH in 1*10
- 8.9
- SFF
- 79.3 %
- SIL in compliance with IEC 61508
- 2
- SIL PAPER
- SIL PAPER
- λges
- 43
Protection Ex - Data
- ATEX - dust labelling
- II 1 D Ex ia IIIC T135 °C …T85 °C Da
- ATEX - gas labelling
- II 1 G Ex ia IIC T4… T6 Ga
- Certificate No. (ATEX)
- KEMA10ATEX0148X
- IECEx - dust labelling
- II 1 D Ex ia IIIC T135 °C …T85 °C Da
- IECEx - gas labelling
- II 1 G Ex ia IIC T4… T6 Ga
- Input power, max. P
- 3 W
- Input voltage, max. U
- 26 V
- Internal capacity, max. C
- < 4 nF
- Internal inductance, max. L
- 0 µH
- Temperature class T4/135°C (-40°C ... +85°C) li
- 350 mA
- Temperature class T5/100°C (-40 ° C ... +75°C) li
- 250 mA
- Temperature class T6/85 °C (-40 °C ... +60°C) li
- 250 mA
Rated Data Iec / En
- Dielectric strength at FG against PE
- ≥ 500 V
- Discharge current I
- 2.5 kA
- Input voltage, max. U
- 26 V
- Lightning test current, I
- 2.5 kA
- Max. continuous voltage, Uc (DC)
- 28 V
- Number of poles
- 1
- Overload - failure mode
- Modus 2
- Protection level on output side Wire-PE 1kV/µs, typically
- 40 V
- Protection level on output side Wire-wire 1 kV/µs, typically
- 40 V
- Protection level on output side Wire-wire 8/20 µs, typically
- 75 V
- Protection level U
- 250 V
- Protection level, U
- 40 V
- Pulse-reset capacity
- ≤ 30 ms
- Rated current I
- 250 mA
- Rated voltage (DC)
- 24 V
- Requirements category acc. to IEC 61643-21
- C1, C2, C3, D1
- Signalling contact
- No
- Signal transmission properties (-3 dB)
- 2.7 MHz
- Standards
- IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006
- Surge current-carrying capacity C1
- < 1 kA 8/20 μs
- Surge current-carrying capacity C2
- 5 kA 8/20 μs
- Surge current-carrying capacity C3
- 100 A 10/1000 μs
- Surge current-carrying capacity D1
- 2.5 kA 10/350 μs
- Voltage type
- DC
- Volume resistance
- 4.7 Ω
Ratings Iecex/Atex/Cul
- ATEX certificate
- ATEX Certificate
- Certificate No. (ATEX)
- KEMA10ATEX0148X
- cUL certificate
- cUL Certificate
- IEC Ex certificate
- IECEX Zertifikat
Temperatures
- Humidity
- 5...96 %
- Operating temperature
- -40 °C...70 °C
- Operating temperature, max.
- 70 °C
- Operating temperature, min.
- -40 °C
- Storage temperature
- -40 °C...80 °C
- Storage temperature, max.
- 80 °C
- Storage temperature, min.
- -40 °C
Tender Specification Sheets
- Long specification
- Surge protection plug for use in connection with the base element VSPC BASE 2SL FG for two wires with a common ground. Two-stage protection circuit in the plug consisting of coarse protection, decoupling resistors and fine protection between the signal wires and the signal ground/ground/earth. Suitable for intrinsically safe powered signal cables EX ia. Version: mechanical identification of the plug to the base element according to the switching type and rated voltage. Protected plug with coding pin and counter-profile for the base element. Optical identification of the protected plug based on the type of protected switching and the voltage level. It is possible to mark the plug.