Weidmuller 8939680000

Free Shipping
1 Year Warranty
A+ Rated On The BBB
10% Off First Order
Based In The USA
Description
Weidmuller 8939680000 is now available from Williams Automation.
If you need a specific firmware version or series for this item, please call or email us with your request. We can also provide specifications and/or a data sheet for this item upon request. Please call or email us if you need one.
We offer Overnight shipping for most items listed on our website. Please get in touch with us to confirm whether the product can ship overnight on the day of your order. Cutoff times are typically 2-3 PM EST. Lead times can range from 1 to 4 business days.
Call (803) 761-7027 if you have any questions about availability, or email us at sales@williamsautomation.com.
Approvals
- Approvals
- CE, CULUS, DNV GL
- ROHS
- Conform
- UL File Number Search
- E141197
Classifications
- eClass 10.0
- 27-21-01-20
- eClass 9.0
- 27-21-01-20
- eClass 9.1
- 27-21-01-90
- ETIM 6.0
- EC002653
- ETIM 7.0
- EC002653
- UNSPSC
- 30-21-18-01
Connection Data
- Clamping range, max.
- 2.5 mm²
- Clamping range, min.
- 0.5 mm²
- Clamping range, rated connection
- 2.5 mm²
- Stripping length, rated connection
- 7 mm
- Type of connection
- Tension-clamp connection
Dimensions And Weights
- Depth
- 112.4 mm
- Depth (inches)
- 4.425 inch
- Length
- 100 mm
- Length (inches)
- 3.937 inch
- Net weight
- 274 g
- Width
- 45 mm
- Width (inches)
- 1.772 inch
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
General Data
- Accuracy
- < 0.1 % span (DC, RTD); 0.2 % span (or 1 °C) + CJ failure
- Configuration
- Using free Windows software, TTA Set Software
- Power consumption
- < 3.5 W
- Step response time
- 50 ms...1 sec (RTD, mV inputs), 110 ms...1 sec (V, mA inputs)
- Temperature coefficient
- < 0.1 % / K (DC, RTD); < 0.1 % FSR / K + CJ error 0.07 °C/K (thermocouples)
- Voltage supply
- 18...264 V AC/DC
Input
- Input current
- -20...+50 mA (min. interval 0.4 mA)
- Input frequency
- 2 Hz…100 kHz
- Input voltage
- -200...500 mV (min. 4 mV span), -20...50 V DC (min. 0.5 V span)
- Number of inputs
- 1
- Potentiometer
- 100 Ω...100 kΩ
- Resistance
- 10 Ω…5 kΩ
- Sensor
- Thermocouples: B, E, J, K, L, N, R, S, T (IEC 60584), PT100, PT1000, (EN 60571) Ni100, Ni1000, (JIS1604), Cu10, Cu25, Cu50, Cu100 (DIN 43760) 2-/3-/4-wire
- Sensor supply
- 24 V DC / 22 mA
Insulation Coordination
- Clearance & creepage distances
- ≥ 5.5 mm (1 mm input/output)
- EMC standards
- EN 55011, EN 61000-6
- Impulse withstand voltage
- 6 kV
- Insulation voltage
- 2.5 kV
- Pollution severity
- 2
- Rated voltage
- 300 V
- Surge voltage category
- III
Output (Analogue)
- Load resistance current
- < 700 Ω
- Load resistance voltage
- > 10 kΩ @ 0...10 V / > 20 kΩ @ -10...+10 V
- Output current
- adjustable between 0 and 20 mA (min. span of 5 mA)
- Output voltage
- adjustable between -10...+10 V (min. span 2.5 V)
- Signal output
- direct or inverted
- Transmit function
- Linear, x1/2, x3/2, x5/2 or user-defined curve (101 points)
Output (Digital)
- Alarm function
- Top and bottom limit values, window range, Over-temperature, Alarm mode: delay, switch on or switch on/off, Holding function can be activated, Delayed 0...4200 s
- Max. switching voltage, AC
- 250 V
- Number of digital outputs
- 2
- Type
- 2 x 1 CO contact (hard gold-plated), Process alarms (4x) with hysteresis, with alarm delay (configurable) 0…180 s
Probability Of Failure
- MTTF
- 138 Years
Product Information
- Product information
- WAS/WAZ6 TTA is a universal signal converter and trip amplifier that can be configured on the PC. Combines the functions of isolation, transmission, linearisation and trip amplification in a single module.These exceptional characteristics and outstanding configurability combine to make the TTA truly unique. The TTA functions with stability and precision under a wide range of voltages and ambient temperatures. It is compatible with all standard sensor types. Universal input signals: temperature signals such as resistance thermometer, thermocouple, potentiometer, frequency transmitter, DC voltage signals and current signalsLoop-powered or passive inputWide-range power supply: 18 – 264 V AC/DCUser-defined linearizationInputs and outputs can be configured on PCCombined analogue and relay outputAmbient temperature range: -40 °C …70 °CThe CBX200 USB interface is used to connect to the PC. The WAS/WAZ6 TTA is also offered as an option with ATEX Zone 2 and UL C1D2 approvals.
Ratings Iecex/Atex/Cul
- Certificate no. (cULus)
- E141197
Temperatures
- Humidity
- 5...95 %, no condensation
- Operating temperature
- -40 °C...70 °C
- Operating temperature, max.
- 70 °C
- Operating temperature, min.
- -40 °C
- Storage temperature
- -40 °C...85 °C
- Storage temperature, max.
- 85 °C
- Storage temperature, min.
- -40 °C
Tender Specification Sheets
- Long specification
- Universal measurement isolating converters and trip amplifiers; can be configured with a PCUniversal measurement isolating converters and trip amplifiers in 45 mm width with external supply for voltage and sensors, for transmitting and isolating analogue DC current-20 to 50 mA, voltages -200 to 500 mV/ -20 to 50 V, 2-/3-/-4-wire RTD, resistors,thermocouples according to IEC 584 and frequencies up to 100 kHz( 2- / 3-wire sensors).Two switching outputs (CO contact) for alarmsand analogue DC voltages (-10 to +10 V) and current outputs (0 to 20 mA) are available on the output side.The component can be configured with a PC using the proprietary TTA-Set software.Add-on housing for TS35 DIN rail installation Dimensions: L/W/H 100/ 45/ 112.4 mm tension-clamp connection/nominal cross-section1.5 mm2Protection degree: IP20 input-20 to 50 mA -200 to 500 mV / -10 to +10 V PT100, PT1000, Ni100, Ni1000, Cu10/25/50/100 2-/3-/4-wire resistance 10 Ohm to 5 kOhm/ Potentiometer100 Ohm to 100 kOhm thermocouple types B, E, J, K, N, R, S, T frequencies 2 Hz to 100 kHz (2-/3-wire sensors) sensor supply 24 VDC / 22 mA outputanalogue0 to 20 mA / adjustable -10 to +10 V/ adjustable relay output/ Alarm 2 CO contacts, hard gold-plated 250 VAC @ 3 A / 30 VDC @ 2A load resistance <700 Ohm/ current/ >10 kOhm/ voltageTransmission errorStep response time< 0,1 % v. E. (DC, RTD)10...90 % < 0,2 % + CJ Fehler (TC)Auxiliary power 18...264 V AC/DCPower loss approx. 3.5 WAmbient temperature range -25 °C...+70 °C< 50 ms...1 s einstellbar< 50 ms...1 s einstellbar< 50 ms...1 s einstellbarIsolation EN 50178 secure 3-way isolation up to 6 kV of all circuits against each otherTest voltage 2.5 kV input against output against auxiliary powerRated voltage 300 V AC/DC at overvoltage category III and pollution degree 2Approvals cULus, GLType WAZ6 TTA
- Short specification
- Universal measurement isolating converters and trip amplifiers; can be configured with PCUniversal measurement isolating converters and trip amplifiers in 45 mm width with external supply for voltage and sensors, for transmitting and isolating analogue DC current -20 to 50 mA, voltages -200 to 500 mV/ -20 to 50 V, 2-/3-/-4-wire RTD, resistors, thermocouples according to IEC 584 and frequencies up to 100 kHz( 2- / 3-wire sensors).Two switching outputs (CO contacts) are available on the output side for alarms.Analogue DC voltage (-10...+10 V) and current outputs (0...20 mA) are available on the output side.The component can be configured with a PC using the proprietary TTA-Set software.
Reviews