Weidmuller 8560730000

Estimated Delivery between and with free shipping.
Overnight shipping is also available.
Free Shipping
1 Year Warranty
A+ Rated On The BBB
10% Off First Order
Based In The USA
Description
Weidmuller 8560730000 is now available from Williams Automation.
If you need a specific firmware version or series for this item, please call or email us with your request. We can also provide specifications and/or a data sheet for this item upon request. Please call or email us if you need one.
We offer Overnight shipping for most items listed on our website. Please get in touch with us to confirm whether the product can ship overnight on the day of your order. Cutoff times are typically 2-3 PM EST. Lead times can range from 1 to 4 business days.
Call (803) 761-7027 if you have any questions about availability, or email us at sales@williamsautomation.com.
Approvals
- Approvals
- CE, CULUSEX, EAC, GERMLLOYD
- ROHS
- Conform
Classifications
- eClass 10.0
- 27-21-01-29
- eClass 9.0
- 27-21-01-29
- eClass 9.1
- 27-21-01-29
- ETIM 6.0
- EC002919
- ETIM 7.0
- EC002919
- UNSPSC
- 31-12-10-07
Connection Data
- Clamping range, max.
- 2.5 mm²
- Clamping range, min.
- 0.5 mm²
- Clamping range, rated connection
- 1.5 mm²
- Stripping length, rated connection
- 7 mm
- Type of connection
- Tension-clamp connection
Dimensions And Weights
- Depth
- 112.4 mm
- Depth (inches)
- 4.425 inch
- Length
- 92.4 mm
- Length (inches)
- 3.638 inch
- Net weight
- 132 g
- Width
- 17.5 mm
- Width (inches)
- 0.689 inch
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
General Data
- Accuracy
- Type K & J: -150°C…1200°C ±(3°C + 0,1% of range), Type T: -150°C…400°C ±(3°C + 0,1% of range), Type E: -150°C…1000°C ±(3°C + 0,1% of range), Type N: -150°C…1300°C ±(3°C + 0,1% of range), Type R & S: 200°C…1760°C ±(6°C + 0,1% of range), Type B: 500°C…1820°C ±(6°C + 0,1% of range)
- Configuration
- DIP switch
- Current-carrying capacity of cross-connect.
- ≤ 2 A
- Galvanic isolation
- 3-way isolator
- Input/Output
- configurable
- Linearity
- Yes
- Power consumption
- 800...850...950 mW at IOUT = 20 mA
- Rail
- TS 35
- Step response time
- without filter: max. 1.4 s; with filter: max. 7.5 s
- Voltage supply
- 24 V DC ± 20 %
Input
- Line resistance in measuring circuit
- 50 Ω
- Number of inputs
- 1
- Sensor
- Thermo element (IEC 584) type: K,J,T,E,N,R,S,B
- Temperature input range
- -200...+1820 °C
Insulation Coordination
- Clearance & creepage distances
- ≥ 3 mm
- EMC standards
- EN 55011, EN 61000-6
- Galvanic isolation
- 3-way isolator
- Impulse withstand voltage
- 4 kV
- Insulation voltage
- 2 kVeff / 5 s
- Insulation voltage input or output/rail
- 4 kVeff / 1 min.
- Insulation voltage input or output/supply
- 2 kVeff / 5 s
- Pollution severity
- 2
- Rated voltage
- 300 V
- Surge voltage category
- III
Output
- cold junction compensation
- Yes
- Fine adjustment
- ± 5% (switchable)
- load impedance current
- ≤ 600 Ω
- load impedance voltage
- ≥ 1 kΩ
- Number of outputs
- 1
- Offset current
- max. 100 µA
- Offset voltage
- max. 0.05 V
- Output current
- 0...20 mA, 4...20 mA
- Output voltage, note
- 0...10 V
- Status indicator
- Module active: LED on/ wire breakage: LED flashing/Error: LED off
- Wire break detection
- LED flashing (output value: > 20 mA, >10 V)
Probability Of Failure
- MTTF
- 270 Years
Product Information
- Product information
- This product will soon be replaced by a new product.Please do not use with new systems. Please contact our technical support.
Temperatures
- Operating temperature
- 0 °C...55 °C
- Operating temperature, max.
- 55 °C
- Operating temperature, min.
- 0 °C
- Storage temperature
- -20 °C...85 °C
- Storage temperature, max.
- 85 °C
- Storage temperature, min.
- -20 °C
Tender Specification Sheets
- Long specification
- TC temperature measurement isolating transformer; configured with DIP switches TC- temperature measurement isolating transformer in 17.5 mm width with external power supply,for transmitting thermocouples (insulated version) types K, J, T, E, N, R, S and B according to IEC 584. Standard DC signals 0(4) to 20 mA / 0 to 10 V are available on the output side.Internal cold-junction compensationPotentiometer is used for zero and span calibrations.Add-on housing for TS35 rail mountingDimensions: L/W/H 92.4/ 17.5/ 112.4 mmTension-clamp connection / Nominal cross-section 1.5 mm2Protection degree: IP 20 Input TC Type Type K, J, T, E, N, R, S Output 0/4...20 mA 0...10 V Load resistance < 600 Ohm/ Strom/> 1 kOhm/ voltageTransmission error 0.2...0.3 0.8 % of input (depending on TC Type)Auxiliary power 24 VDC +/- 25 %Power loss approx. 0.9 WAmbient temperature range 0°C...+55 °C Isolation EN 50178, 3-way isolation up to 4 kV AC/DC of all circuits against each otherTest voltage 2 kV input against output against auxiliary powerRated voltage 300 V AC/DC at overvoltage category III and pollution degree 2Approvals cULus, cULusEXType WAZ5 PRO Thermo
- Short specification
- TC temperature measurement isolating transformer; configured with DIP switches TC- temperature measurement isolating transformer in 17.5 mm width with external power supply,for transmitting thermocouples (insulated version) types K, J, T, E, N, R, S and B according to IEC 584. Standard DC signals 0(4) to 20 mA / 0 to 10 V are available on the output side.Internal cold-junction compensation Potentiometer for zero/span compensation