Weidmuller 8543820000

Estimated Delivery between and with free shipping.
Overnight shipping is also available.
Free Shipping
1 Year Warranty
A+ Rated On The BBB
10% Off First Order
Based In The USA
Description
Weidmuller 8543820000 is now available from Williams Automation.
If you need a specific firmware version or series for this item, please call or email us with your request. We can also provide specifications and/or a data sheet for this item upon request. Please call or email us if you need one.
We offer Overnight shipping for most items listed on our website. Please get in touch with us to confirm whether the product can ship overnight on the day of your order. Cutoff times are typically 2-3 PM EST. Lead times can range from 1 to 4 business days.
Call (803) 761-7027 if you have any questions about availability, or email us at sales@williamsautomation.com.
Approvals
- Approvals
- CE, CULUS
- ROHS
- Conform
- UL File Number Search
- E141197
Classifications
- eClass 10.0
- 27-21-01-20
- eClass 9.0
- 27-21-01-20
- eClass 9.1
- 27-21-01-20
- ETIM 6.0
- EC002653
- ETIM 7.0
- EC002653
Connection Data
- Clamping range, max.
- 2.5 mm²
- Clamping range, min.
- 0.5 mm²
- Clamping range, rated connection
- 2.5 mm²
- Type of connection
- Screw connection
Dimensions And Weights
- Depth
- 112.4 mm
- Depth (inches)
- 4.425 inch
- Length
- 92.4 mm
- Length (inches)
- 3.638 inch
- Net weight
- 110.1 g
- Weight
- 137 g
- Width
- 17.5 mm
- Width (inches)
- 0.689 inch
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
General Data
- Accuracy
- Repeat accuracy: max. ± 0.3% of measuring range end value (10 V/ 20 mA)
- Configuration
- DIP switch, Potentiometer
- Current-carrying capacity of cross-connect.
- ≤ 2 A
- Galvanic isolation
- 3-way isolator
- Input/Output
- 0...10 V, 0(4)...20 mA / 2 CO contact
- Power consumption
- Typ.: 1 W both relays picked up
- Rail
- TS 35
- Temperature coefficient
- ≤ 500 ppm/K
- Voltage supply
- 24 V DC ± 25 %
Input
- Input current
- 0(4)...20 mA
- Input resistance, current
- ≤ 110 Ω
- Input resistance, voltage
- ≥ 100 kΩ
- Input voltage
- 0...10 V
- Number of inputs
- 1
Insulation Coordination
- Clearance & creepage distances
- ≥ 3 mm
- EMC standards
- EN 61000-4-2, -3, -4, -5, -6
- Galvanic isolation
- 3-way isolator
- Impulse withstand voltage
- 4 kV
- Insulation voltage
- 2 kVeff / 5 s
- Pollution severity
- 2
- Rated voltage
- 300 V
- Surge voltage category
- III
Output
- Contact material
- AgNi 90/10
- Status indicator
- LED green ON: OK, LED red ON: alarm (per channel)
- Switching thresholds
- 1...90 % (independently for channel 1 and channel 2)
Output (Digital)
- Alarm function
- configurable, High or low alarm, Hysteresis 5% / 10%
- Contact material
- AgNi 90/10
- Continuous current
- 3 A
- Hysteresis
- 1...10 % (independent for channel 1 and channel 2)
- Max. switching voltage, AC
- 250 V
- Type
- 2 CO contacts, Open or closed-circuit principle
Probability Of Failure
- MTTF
- 369 Years
Product Information
- Product information
- This product will soon be replaced by a new product.Please do not use with new systems. Please contact our technical support.
Ratings Iecex/Atex/Cul
- Certificate no. (cULus)
- E141197
Temperatures
- Humidity
- 40 °C / 93 % rel. humidity, no condensation
- Operating temperature
- 0 °C...55 °C
- Operating temperature, max.
- 55 °C
- Operating temperature, min.
- 0 °C
- Storage temperature
- -20 °C...85 °C
- Storage temperature, max.
- 85 °C
- Storage temperature, min.
- -20 °C
Tender Specification Sheets
- Long specification
- Limit-value monitoring component for DC- current-/ voltage standard signals with relay output and 3-way electrical isolation.Limit-value monitoring component in 22.5 mm width for recording 0(4)...20 mA / 0...10 V standard signals. Two relay contacts (COs), each with a switching capacity of 750 VA, are available on the output side for monitoring an upper and lower limit. The switching behaviour (high/low trip, fail-safe) can be selected using DIP switches. Switching thresholds and hystereses can be adjusted with the front-side potentiometer. The component has 4 kV of 3-way isolation and is supplied externally with 24 VDC. Add-on housing for TS35 rail mounting Dimensions: L/W/H 92.4/ 22.5/ 112.4 mm Screw connection / Nominal cross-section 2.5 mm2Protection degree: IP 20 Input 0(4)...20 mA / 0...10 VOutput 2 x relay / CO Open-circuit/closed-circuit principle Switching current 3 A Switching voltage 6... 250 V AC / 6...60 V DC Switching thresholds 1...90 % via potentiometer (independently for channels 1 and 2)Hysteresis 1% ... 10 % via potentiometer (independently for channels 1 and 2) Temperature coefficient < 500 ppm K Step response time < 60 ms (10...90 %)Auxiliary power 24 VDC +/- 25 % Ambient temperature range 0 °C...+55 °C Secure isolation EN 50178, 3-way Isolation up to 4 kVTest voltage 2 kVeff / 5s Input / Output/ SupplyRated voltage 300 V AC/DC at overvoltage category III and pollution degree 2 Approvals cULus Type WAS5 DC/Alarm
- Short specification
- Limit-value monitoring component for DC- current/voltage standard signals with relay output and 3-way electrical isolation.Limit-value monitoring component in 22.5 mm width for recording 0(4)...20 mA / 0...10 V standard signals. Two relay contacts (COs), each with a switching capacity of 750 VA, are available on the output side for monitoring an upper and lower limit. The switching behaviour (high/low trip, fail-safe) can be selected using DIP switches. Switching thresholds and hystereses can be adjusted with the front-side potentiometer. The component has 4 kV of 3-way isolation and is supplied externally with 24 VDC.
Reviews
What our customers say
Rating