Weidmuller 8528650000

Estimated Delivery between and with free shipping.
Overnight shipping is also available.
Free Shipping
1 Year Warranty
A+ Rated On The BBB
Next Day Delivery
Based In The USA
Description
Weidmuller 8528650000 is now available new, surplus, and used from Williams Automation.
If you need a specific firmware or series relating to this item, please call or email us with your request.
We can also provide specifications and/or a data sheet for this item upon request. Please call or email us if you require one.
Please note we offer UPS Next Day Air shipping for all orders. Please be sure to select next day shipping at checkout, and we will provide same-day shipment.
Call (803) 761-7027 if you have any questions about availability, or email us at sales@williamsautomation.com.
Approvals
- Approvals
- CE, CULUS, EAC
- ROHS
- Conform
- UL File Number Search
- E141197
Classifications
- eClass 10.0
- 27-21-01-20
- eClass 9.0
- 27-21-01-20
- eClass 9.1
- 27-21-01-20
- ETIM 6.0
- EC002653
- ETIM 7.0
- EC002653
- UNSPSC
- 30-21-18-01
Connection Data
- Clamping range, max.
- 2.5 mm²
- Clamping range, min.
- 0.5 mm²
- Clamping range, rated connection
- 2.5 mm²
- Type of connection
- Screw connection
- Wire connection method
- Screw connection
Dimensions And Weights
- Depth
- 112.4 mm
- Depth (inches)
- 4.425 inch
- Length
- 72 mm
- Length (inches)
- 2.835 inch
- Net weight
- 100.7 g
- Weight
- 150 g
- Width
- 22.5 mm
- Width (inches)
- 0.886 inch
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
General Data
- Accuracy
- 0.5 % FSR
- Configuration
- DIP switch
- Galvanic isolation
- 2-way isolator
- Input/Output
- 1 /5/ 10 A AC / 4...20 mA (current loop)
- Rail
- TS 35
- Step response time
- typ. 700 ms
- Temperature coefficient
- ≤ 200 ppm/K
- Voltage supply
- 13...30 V DC, via output current loop
Input
- Input current
- 0...1 A AC/ 0...5 A AC/ 0...10 A AC
- Input frequency
- 50...60Hz
- Number of inputs
- 1
Insulation Coordination
- Clearance & creepage distances
- ≥ 5.5 mm
- EMC standards
- EN 55011, EN 61000-6
- Galvanic isolation
- 2-way isolator
- Impulse withstand voltage
- 6 kV
- Insulation voltage
- 4 kVeff / 5 s
- Pollution severity
- 2
- Rated voltage
- 300 V
- Surge voltage category
- III
Output
- load impedance current
- ≤ 600 Ω
- Number of outputs
- 1
- Offset current
- max. 100 µA
- Output current
- 4...20 mA (current loop)
- Output signal limit
- Approx. 24 mA
- Status indicator
- LED ON: OK; LED flashing: signal out of range;LED OFF: Error
Probability Of Failure
- MTTF
- 564 Years
Product Information
- Product information
- This product will soon be replaced by a new product.Please do not use with new systems. Please contact our technical support.
Ratings Iecex/Atex/Cul
- Certificate no. (cULus)
- E141197
Temperatures
- Operating temperature
- 0 °C...50 °C
- Operating temperature, max.
- 50 °C
- Operating temperature, min.
- 0 °C
- Storage temperature
- -20 °C...70 °C
- Storage temperature, max.
- 70 °C
- Storage temperature, min.
- -20 °C
Tender Specification Sheets
- Long specification
- Monitoring component for AC currents up to 10A with 4...20 mA loop feedand electrical isolationCurrent monitoring component in 22.5 mm width for recording 50/ 60 Hz AC currents0...1 A / 0...5 A / 0...10 A. Input range can be selected using DIP switches.Power is fed to the component via the 4...20 mA current loop on the output side.The input and output circuits have 6 kV of electrical isolation.Add-on housing for TS35 rail mountingDimensions: L/W/H 72/ 22.5/ 92.4 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20 Input 0...1 A / 0...5 A / 0...10 A AC switchable 50 / 60 HzVoltage of measuring circuit 250 V ACOutput 4...20 mA current loopLoad resistance < 600 Ohm Strom>1 kOhm / voltageTransmission error < 0,5% v. E. Temperature coefficient 200 ppm / KStep response time typ. 700 msAuxiliary power via output-side current loopAmbient temperature range 0 °C...+50 °CSecure isolation EN 50178, 2-way isolation up to 6 kVTest voltage 4 kV input against outputRated voltage 300 V AC/DC at overvoltage category III and pollution degree 2Approvals cULusType WAS1 CMA LP 1/5/10A ac
- Short specification
- Monitoring component for AC currents up to 10A with 4...20 mA loop feedand electrical isolationCurrent monitoring component in 22.5 mm width for recording 50/ 60 Hz AC currents0...1 A / 0...5 A / 0...10 A. Input range can be selected using DIP switches.Power is fed to the component via the 4...20 mA current loop on the output side.The input and output circuits have 6 kV of electrical isolation.