Weidmuller 8425720000

Free Shipping
1 Year Warranty
A+ Rated On The BBB
10% Off First Order
Based In The USA
Description
Weidmuller 8425720000 is now available from Williams Automation.
If you need a specific firmware version or series for this item, please call or email us with your request. We can also provide specifications and/or a data sheet for this item upon request. Please call or email us if you need one.
We offer Overnight shipping for most items listed on our website. Please get in touch with us to confirm whether the product can ship overnight on the day of your order. Cutoff times are typically 2-3 PM EST. Lead times can range from 1 to 4 business days.
Call (803) 761-7027 if you have any questions about availability, or email us at sales@williamsautomation.com.
Approvals
- Approvals
- CE, CSA, cURus, EAC
- ROHS
- Conform
- UL File Number Search
- E141197
Classifications
- eClass 10.0
- 27-21-01-29
- eClass 9.0
- 27-21-01-29
- eClass 9.1
- 27-21-01-29
- ETIM 6.0
- EC002919
- ETIM 7.0
- EC002919
- UNSPSC
- 30-21-18-01
Connection Data
- Clamping range, max.
- 1.5 mm²
- Clamping range, min.
- 0.5 mm²
- Clamping range, rated connection
- 1.5 mm²
- Conductor cross-section, flexible, AEH (DIN 46228-1), max.
- 1.5 mm²
- Conductor cross-section, flexible, AEH (DIN 46228-1), min.
- 0.5 mm²
- Type of connection
- Tension-clamp connection
- Wire connection cross section AWG, max.
- AWG 16
- Wire connection cross section AWG, min.
- AWG 26
- Wire connection cross section, finely stranded, max.
- 1.5 mm²
- Wire connection cross-section, finely stranded, min.
- 0.5 mm²
- Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
- 1.5 mm²
- Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
- 0.5 mm²
- Wire cross-section, finely stranded, max. (AWG)
- AWG 16
- Wire cross-section, finely stranded, min. (AWG)
- AWG 26
- Wire cross-section, solid, max.
- 1.5 mm²
- Wire cross-section, solid, min.
- 0.5 mm²
Dimensions And Weights
- Depth
- 63.2 mm
- Depth (inches)
- 2.488 inch
- Length
- 91 mm
- Length (inches)
- 3.583 inch
- Net weight
- 29 g
- Width
- 6 mm
- Width (inches)
- 0.236 inch
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
General Data
- Accuracy
- Typ.: 0.2 %, máx. 0.5 % v. FSR
- Configuration
- none
- Galvanic isolation
- between input/output
- Input/Output
- PT100/ 4...20 mA (current loop)
- Linearity
- Yes
- Rail
- TS 35
- Step response time
- 10 ms
- Temperature coefficient
- max. ± 250 ppm/K
- Voltage supply
- Output loop powered, max. 30 V/ min. 9 V + (20 mA x RL)
Input
- Number of inputs
- 1
- Sensor
- PT100/2-/3-wire (in compliance with IEC 751)
- Sensor supply
- 0.8 mA / 9…30 V DC
- Temperature input range
- 0...100 °C
Insulation Coordination
- EMC standards
- EN 61000-6
- Galvanic isolation
- between input/output
- Pollution severity
- 2
- Rated voltage
- 50 V
- Surge voltage category
- I
Output
- load impedance current
- ≤ 600 Ω
- Number of outputs
- 1
- Output current
- 4...20 mA (current loop) at 9...30V DC
Probability Of Failure
- MTTF
- 1,066 Years
Rated Data Ul
- Certificate No. (cURus)
- E141197
Temperatures
- Operating temperature
- -25 °C...50 °C
- Operating temperature, max.
- 50 °C
- Operating temperature, min.
- -25 °C
- Storage temperature
- -25 °C...85 °C
- Storage temperature, max.
- 85 °C
- Storage temperature, min.
- -25 °C
Tender Specification Sheets
- Long specification
- PT100 temperature measuring transformer, output-loop powered,3-wire connection technologyRTD measuring transformer in 6 mm width, 4...20 mA output-loop poweredwithout electrical isolation, for transmitting PT100 2-/3-wire signals.Input temperature range 0...+100 °C.Add-on housing for TS35 rail mountingDimensions: L/W/H 91/ 6/ 63.2 mmTension-clamp connection / Nominal cross-section 1.5 mm2Protection degree: IP 20 Input PT100, 2-/3-wireOutput 4...20 mALoad resistance Transmission error Auxiliary power via 4...20 mA current loopAmbient temperature range 0°C...+50 °C< 0,2 % v. E.Isolation no electrical isolationApprovals cURus, CSATypeMCZ PT100/3 CLP 0...100C
- Short specification
- PT100 temperature measuring transformer, output-loop powered,3-wire connection technologyRTD measuring transformer in 6 mm width, 4...20 mA output-loop poweredwithout electrical isolation, for transmitting PT100 2-/3-wire signals.Input temperature range 0...+100 °C.
Reviews