Weidmuller 7760054124

Estimated Delivery between and with free shipping.
Overnight shipping is also available.
Free Shipping
1 Year Warranty
A+ Rated On The BBB
10% Off First Order
Based In The USA
Description
Weidmuller 7760054124 is now available from Williams Automation.
If you need a specific firmware version or series for this item, please call or email us with your request. We can also provide specifications and/or a data sheet for this item upon request. Please call or email us if you need one.
We offer Overnight shipping for most items listed on our website. Please get in touch with us to confirm whether the product can ship overnight on the day of your order. Cutoff times are typically 2-3 PM EST. Lead times can range from 1 to 4 business days.
Call (803) 761-7027 if you have any questions about availability, or email us at sales@williamsautomation.com.
Approvals
- Approvals
- EAC
Classifications
- eClass 10.0
- 27-21-01-23
- eClass 9.0
- 27-21-01-23
- eClass 9.1
- 27-21-01-23
- ETIM 6.0
- EC002475
- ETIM 7.0
- EC002475
Connection Data
- Clamping range, max.
- 2.5 mm²
- Clamping range, min.
- 0.5 mm²
- Clamping range, rated connection
- 2.5 mm²
- Tightening torque, max.
- 0.6 Nm
- Tightening torque, min.
- 0.4 Nm
- Type of connection
- Screw connection
- Wire connection cross section AWG, max.
- AWG 12
- Wire connection cross section AWG, min.
- AWG 26
Dimensions And Weights
- Depth
- 114 mm
- Depth (inches)
- 4.488 inch
- Height
- 117.2 mm
- Height (inches)
- 4.614 inch
- Net weight
- 110 g
- Weight
- 136 g
- Width
- 12.5 mm
- Width (inches)
- 0.492 inch
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
General Data
- Accuracy
- < 0.1 % of end value
- Configuration
- none
- Galvanic isolation
- 2-way isolator
- Rail
- TS 35
- Step response time
- ≤ 1 ms
- Temperature coefficient
- ≤ 100 ppm/K
- Voltage supply
- Loop powered, via 4…20 mA input
Input
- Input current
- 0(4)...20 mA current loop
- Number of inputs
- 2
- Sensor
- Current source
- Voltage drop, current input
- 3.8 V, Approx. 3 V at RL = 0 Ω; approx. 13 V at RL = 500 Ω; (IIN =20 mA)
Insulation Coordination
- EMC standards
- EN 61010-1:2011, UL 61010-1, IEC61000-6-2, IEC 61000-6-4
- Galvanic isolation
- 2-way isolator
- Impulse withstand voltage
- 4 kV (1.2/50 µs)
- Insulation voltage
- 2 kV inputs / outputs
- Pollution severity
- 2
- Rated voltage
- 300 V
- Surge voltage category
- III
Output
- load impedance current
- ≤ 600 Ω
- Number of outputs
- 2
- Output current
- 0(4)...20 mA
Product Information
- Product information
- The ACT20P-2CI-2CO-ILP-S (dual channel) fixed passive isolators isolate analogue standard current source signals. An analogue input current signal is converted linear and galvanic isolated into an analogue output current signal. The device is powered via the input current loop. Features Galvanic 4-way isolation (dual-channel device) between all inputs and outputs.
Temperatures
- Ambient temperature
- -20 °C...+60 °C
- Humidity
- 5...95 %, no condensation
All Weidmuller
Reviews
What our customers say
Rating