Ambient conditions
- Ambient temperature (operation)
- -25 °C - 75 °C
- Ambient temperature (storage/transport)
- -25 °C - 75 °C
Connection, equipotential bonding, information technology
- Connection method
- Via protective contact plug
Connection (protective circuit, power supply)
- Connection method
- Grounding plug/socket
- Connection method IN
- Grounding plug
- Connection method OUT
- Grounding socket
Environmental Product Compliance
- REACh SVHC
- Lead 7439-92-1
Power supply, general
- Connection method
- RJ12
- Connection method IN
- RJ12 female connector
- Connection method OUT
- RJ12 female connector
Protective circuit, information technology
- Alternating current carrying capacity (line-earth)
- 10 A - 1 s
- Alternating current carrying capacity (line-line)
- 250 mA - 1 s
- Arrester rated voltage UC
- 200 V DC
- Capacity (line-earth)
- typ. 5 pF
- Capacity (line-line)
- typ. 1 nF
- Cut-off frequency fg (3 dB), sym. in 100 Ohm system
- typ. 4 MHz
- Cut-off frequency fg (3 dB), sym. in 150 Ohm system
- typ. 3 MHz
- Cut-off frequency fg (3 dB), sym. in 600 Ohm system
- typ. 700 kHz
- Impulse durability (line-earth)
- D1 - 500 A
- C3 - 100 A
- C2 - 4 kV / 2 kA
- Impulse durability (line-line)
- C3 - 25 A
- C2 - 2 kV / 1 kA
- Insulation resistance Riso
- ≥ 1 MΩ
- ≥ 1 GΩ
- Max. discharge current Imax (8/20) µs
- 2.5 kA
- Nominal discharge current In (8/20) µs (line-earth)
- 2.5 kA
- Nominal discharge current In (8/20) µs (line-line)
- 1 kA
- Operating effective current IC at UC
- ≤ 150 µA
- Output voltage limitation at 1 kV/µs (wire-wire)
- ≤ 360 V
- Pulse reset time (line-line)
- ≤ 15 ms
- Rated current
- 150 mA (25 °C)
- Residual current IPE
- ≤ 2 µA
- Residual voltage at In (line-earth)
- ≤ 30 V
- Residual voltage at In (line-line)
- ≤ 500 V
- Residual voltage with Ian (10/1000) µs (line-earth)
- ≤ 35 V
- Residual voltage with Ian (10/1000) µs (line-line)
- ≤ 35 V
- Response time tA (line-earth)
- ≤ 100 ns
- Response time tA (line-line)
- ≤ 25 ns
- Voltage protection level Up (line-earth)
- ≤ 900 V (C3 - 100 A)
- ≤ 900 V (C2 - 2 kA)
- Voltage protection level Up (line-line)
- ≤ 350 V (C3 - 25 A)
- ≤ 460 V (C2 - 1 kA)
Protective circuit, power supply
- Arrester rated voltage UC (L-N)
- 275 V AC
- Arrester rated voltage UC (L-PE)
- 360 V AC
- Arrester rated voltage UC (N-PE)
- 360 V AC
- Combination wave UOC
- 4 kV
- Energy absorption symmetrical
- 140 J (L-N)
- Enery absorption, asymmetrical
- 220 J (L(N)-PE)
- EN type
- T3
- Max. required back-up fuse
- 16 A (gG / B / C)
- Nominal discharge current In (8/20) µs
- 3 kA (> 5x)
- Nominal frequency fN
- 50 Hz (60 Hz)
- Nominal voltage UN
- 230 V AC
- Rated load current IL
- 16 A (30 °C)
- Residual current IPE
- ≤ 5 µA
- Response time (L-N)
- ≤ 25 ns
- Response time (L-PE)
- ≤ 100 ns
- Response time (N-PE)
- ≤ 100 ns
- Standby power consumption PC
- ≤ 1 VA
- Surge protection fault message
- optical
- Voltage protection level Up (L-N)
- ≤ 1.2 kV
- Voltage protection level Up (L-PE)
- ≤ 1.5 kV
- Voltage protection level Up (N-PE)
- ≤ 1.5 kV
Standards (protective circuit, information technology)
- IEC test classification
- C2
- C1
- C3
- D1