Phoenix Contact 2701159

Free Shipping
1 Year Warranty
A+ Rated On The BBB
10% Off First Order
Based In The USA
Description
Phoenix Contact 2701159 is now available from Williams Automation.
If you need a specific firmware version or series for this item, please call or email us with your request. We can also provide specifications and/or a data sheet for this item upon request. Please call or email us if you need one.
We offer Overnight shipping for most items listed on our website. Please get in touch with us to confirm whether the product can ship overnight on the day of your order. Cutoff times are typically 2-3 PM EST. Lead times can range from 1 to 4 business days.
Call (803) 761-7027 if you have any questions about availability, or email us at sales@williamsautomation.com.
Ambient conditions
- Air pressure (operation)
- 70 kPa - 106 kPa (up to 3000 m above sea level)
- Air pressure (storage/transport)
- 70 kPa - 106 kPa (up to 3000 m above sea level)
- Ambient temperature (operation)
- -25 °C - 55 °C (Standard)
- -40 °C - 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
- Ambient temperature (storage/transport)
- -40 °C - 85 °C
- Degree of protection
- IP20
- Permissible humidity (operation)
- 10 % - 95 % (according to DIN EN 61131-2)
- Permissible humidity (storage/transport)
- 10 % - 95 % (according to DIN EN 61131-2)
Analog inputs
- A/D conversion time
- approx. 10 µs
- Connection method
- Inline shield connector
- Connection technology
- 2-wire
- Current input signal
- 0 mA - 20 mA
- 4 mA - 20 mA
- -40 mA - 40 mA
- -20 mA - 20 mA
- 0 mA - 40 mA
- Data formats
- IB IL, IB ST, IB RT, standardized representation, PIO format
- Description of the input
- Single-ended inputs, voltage or current
- Filtering
- 1st order low pass
- Input name
- Analog inputs
- Input resistance current input
- 25 Ω (Shunt)
- Input resistance of voltage input
- > 240 kΩ
- Limit frequency (3 dB)
- 3.5 kHz
- Measured value representation
- 16 bit two's complement
- Measured value resolution
- 16 bits (15 bits + sign bit)
- Measuring principle
- Successive approximation
- Note regarding the connection technology
- shielded
- Number of inputs
- 8
- Resolution A/D
- 16 bit
- Type of protection
- Surge protection, overcurrent protection
- Voltage input signal
- -10 V - 10 V
- 0 V - 50 V
- -25 V - 25 V
- 0 V - 10 V
- 0 V - 25 V
- 0 V - 5 V
- -5 V - 5 V
Dimensions
- Depth
- 71.5 mm
- Height
- 136.8 mm
- Note on dimensions
- Housing dimensions
- Width
- 48.8 mm
Electrical isolation
- Test section
- I/O / functional earth ground 500 V AC 50 Hz 1 min.
- 7.5 V supply (bus logic), 24 V supply UANA / I/O 500 V AC 50 Hz 1 min.
- 5 V supply, outgoing remote bus/7.5 V supply (bus logics) 500 V AC 50 Hz 1 min.
- 7.5 V supply (bus logic), 24 V supply UANA/functional earth ground 500 V AC 50 Hz 1 min.
- 5 V supply, incoming remote bus/7.5 V supply (bus logics) 500 V AC 50 Hz 1 min.
Environmental Product Compliance
- China RoHS
- Environmentally friendly use period: unlimited = EFUP-e
- No hazardous substances above threshold values
Inline potentials
- Current consumption
- typ. 48 A
- max. 35 mA
- max. 55 mA
- typ. 24 mA
- Designation
- Communications power (UL)
- Supply of analog modules (UANA)
- Supply voltage
- 7.5 V DC (via voltage jumper)
- 24 V DC
- Supply voltage range
- 19.2 V DC - 30 V DC (including all tolerances, including ripple)
Interfaces
- Connection method
- Inline data jumper
- Designation
- Inline local bus
- Transmission physics
- Copper
- Transmission speed
- 500 kbps
Note
- Utilization restriction
- EMC: class A product, see manufacturer's declaration in the download area
Standards and Regulations
- Connection in acc. with standard
- CUL
- Protection class
- III, IEC 61140, EN 61140, VDE 0140-1
All Phoenix Contact
Reviews
What our customers say
Rating