OMRON E6B2-CWZ6C 1000P/R 2M
Description
OMRON E6B2-CWZ6C 1000P/R 2M is now available new, surplus, and used from Williams Automation.
If you need a specific firmware or series relating to this item, please call or email us with your request.
We can also provide specifications and/or a data sheet for this item upon request. Please call or email us if you require one.
Please note we offer UPS Next Day Air shipping for all orders. Please be sure to select next day shipping at checkout, and we will provide same-day shipment.
Call (803) 761-7027 if you have any questions about availability, or email us at sales@williamsautomation.com.
Ratings / Performance
- Accessories
- Instruction manual, coupling and hex-head spanner
- Ambient humidity
- Storage: 35 to 85%RH
- Operating: 35 to 85%RH
- Ambient temperature
- Storage: -25 to 85 °C
- Operating: -10 to 70 °C
- Connection method
- Pre-wired models(Cable_length: 2 m)
- Control output (Load current)
- 35mA max.(Sink current)
- Control output (Output type)
- NPN open collector output
- Control output (Residual voltage)
- 0.4 VDC max.(load current:at 35mA Max.)
- Current consumption
- 80 mA DC Max.
- Degree of protection
- IEC60529: IP50
- Dielectric strength
- 500 VAC at 50/60 Hz for 1 minute between charged parts and the case
- Encoding method
- Incremental
- Inrush current
- approx. 9A(Time : approx.0.3ms)
- Insulation resistance
- 20 MOhm min. at 500 VDC between charged parts and the case
- Load power supply voltage
- 30 VDC max.
- Material (body)
- Aluminum
- Material (case)
- ABS
- Material (shaft)
- SUS420J2
- Max. permissible rotation
- 6000 r/min
- Max. response frequency
- 100 kHz
- Mechanical life expectancy
- 100 million rotations min.
- Moment of inertia
- 1 x 10**-6 kg.m**2 max.
- Output phases
- A, B and Z
- Phase difference on output
- 90 DEG -45 to +45 DEG
- Power supply voltage
- DC5 to 24 V (ripple (p-p): 5% max.)
- Protective circuit
- Power supply reverce polarity protection
- Output short cut protection
- Resolution (Single turn type)
- 1000 P/R
- Rise and_fall times of output
- Rise time of output: 1 μs max.
- Fall time of output: 1 μs max.
- (Output voltage: 5V, load resistance: 1k OHM, cable length: 2m Max.)
- Shaft loading
- Thrust: 20 N
- Radial: 30 N
- Shock resistance
- 1000 m/s**2 for 3 times each in X, Y, and Z directions
- Starting positional point
- Equipped
- Starting torque
- Room temperature: 0.98 mN.m max.
- Vibration resistance
- 10 to 500 Hz, 2-mm or 150 m/s**2 double amplitude for 11 min 3 times each in X, Y, and Z directions