OMRON E2E-X1R5E1-M1
Description
OMRON E2E-X1R5E1-M1 is now available new, surplus, and used from Williams Automation.
If you need a specific firmware or series relating to this item, please call or email us with your request.
We can also provide specifications and/or a data sheet for this item upon request. Please call or email us if you require one.
Please note we offer UPS Next Day Air shipping for all orders. Please be sure to select next day shipping at checkout, and we will provide same-day shipment.
Call (803) 761-7027 if you have any questions about availability, or email us at sales@williamsautomation.com.
Ratings / Performance
- Accessories
- Instruction manual
- Ambient humidity
- Storage: 3595%RH
- Operating: 35 to 95%RH
- Ambient temperature
- Storage: -40 to 85 °C
- Operating: -40 to 85 °C
- Connection method
- M12 connector models
- Control output (Output type)
- NPN voltage-current output
- Control output (Residual voltage)
- 2 V Max.(under load current with cable length of 2 m)
- Control output (Switching capacity)
- 0 to 200 mA
- Current consumption
- 13 mA max.
- Degree of protection
- IEC60529: IP67
- Dielectric strength
- 1000 VAC 50/60 Hz for 1 minute between charged parts and the case
- Differential distance
- 10% Max. of sensing distance
- Indicator
- Operation indicator (red)
- Insulation resistance
- 50 MOhm Min. at 500 VDC between charged parts and the case
- Material (case)
- Stainless steel (SUS303)
- Material (clamping nuts)
- Brass nickel plating
- Material (sensing surface)
- PBT
- Material (toothed washer)
- Iron zinc plating
- Operating voltage range
- 12 to 24 VDC
- Operation mode
- NO
- Power supply voltage
- 12 to 24 VDC ripple(p-p) 10% Max.
- Protective circuit
- Surge suppressor
- Output short-cut protection
- Power supply reverse polarity protection
- Sensing distance
- 1.5 mm-10% to +10%
- Sensing method
- Inductive type
- Sensing object
- Ferrous metal (Sensitivity lowers with non-ferrous metals.)
- Setting distance
- 0 to 1.2 mm
- Shock resistance
- 500 m/s**2 for 10 times each in X, Y, and Z directions
- Standard or Different frequency
- Standard
- Standard sensing object
- Iron 8 x 8 x 1 mm
- Temperature influence
- +/- 10% Max. of sensing distance in temperature range of -25 to +70 CEL
- +/- 15% Max. of sensing distance in temperature range of -40 to +85 CEL
- (As the basis for sensing distance of 23 CEL
- Type
- Shielded
- Vibration resistance
- 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
- Voltage influence
- +/- 1% Max. of sensing distance in rated voltage range +/- 15%.
- (As the basis for sensing distance at standard power voltage)
- Weight (Packed state)
- approx. 15 g