OMRON D4MC-2000
Description
OMRON D4MC-2000 is now available new, surplus, and used from Williams Automation.
If you need a specific firmware or series relating to this item, please call or email us with your request.
We can also provide specifications and/or a data sheet for this item upon request. Please call or email us if you require one.
Please note we offer UPS Next Day Air shipping for all orders. Please be sure to select next day shipping at checkout, and we will provide same-day shipment.
Call (803) 761-7027 if you have any questions about availability, or email us at sales@williamsautomation.com.
Ratings / Performance
- Actuator
- Hinge roller lever
- Ambient humidity
- Operating: 35 to 95%
- Ambient temperature
- Operating: -10 to 80 °C
- Contact configuration
- Single-Pole, Double-Throw type
- Contact form
- SPDT
- Contact resistance
- 15 mOhm Max. (Initial value)
- (Measuring method is contact resistance meter.)
- Degree of protection
- IEC60529 (JEM): IP67
- Dielectric strength
- Between each terminal and non-live-metallic part: 2000 V
- Between each terminal of the same polarities: 1000 V
- Between live-metallic part and ground: 2000 V
- (50/60 Hz for 1 min)
- Durability (Electrically)
- (Temperature, Humidity conditions: 20 +/- 2 CEL, 65 +/- 5 %RH)
- 500,000 operations Min. (Resistive load 10 A at 125 VAC) * When operate the actuator with the specified value of the Over Travel. (Resistive load 10 A at 125 VAC)
- Durability (Mechanically)
- 10,000,000 operations Min. (No load)
- (Temperature, Humidity conditions: 20 +/- 2 CEL, 65 +/- 5 %RH)
- Free Position (FP)
- Standard value 51 mm Max.
- Frequency
- 50/60 Hz
- Inrush current
- NO: 15 A
- NC: 30 A
- Insulation resistance
- Between each terminal of the same polarities: 100 MΩ
- Between each terminal and non-live-metallic part: 100 MΩ
- (at 500 VDC Megger)
- Between live-metallic part and ground: 100 MΩ
- Load
- General load
- Mounting specification
- Side mounting
- Movement Differential (MD)
- Standard value 3 mm Max.
- Operating Force (OF)
- Standard value Max. 1.96 N
- Operating mechanism
- Snap action
- Operating Position (OP)
- Standard value 40 +/- 1 mm
- Over-Travel (OT)
- Standard value 5 mm Min.
- Permissible operating frequency (Electrically)
- 20 operations / 1 minute Max.
- Permissible operating frequency (Mechanically)
- 120 operations / 1 minute Max.
- Permissible operating speed
- 0.05 mm/s to 0.5 m/s
- Ratings (AC): Inductive load
- Rated voltage: 480 VAC / Inductive load: 2.5 A(NC) 2.5 A(NO) / Motor load: 1.5 A(NC) 0.75 A(NO)
- Rated voltage: 125 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
- Rated voltage: 250 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 3 A(NC) 1.5 A(NO)
- Ratings (AC): Non-Inductive load
- Rated voltage: 250 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2.5 A(NC) 1.25 A(NO)
- Rated voltage: 480 VAC / Resistive load: 3 A(NC) 3 A(NO) / Lamp load: 1.5 A(NC) 0.75 A(NO)
- Rated voltage: 125 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
- Ratings (DC): Inductive load
- Rated voltage: 30 VDC / Inductive load: 5 A(NC) 5 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
- Rated voltage: 8 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
- Rated voltage: 250 VDC / Inductive load: 0.03 A(NC) 0.03 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)
- Rated voltage: 14 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
- Rated voltage: 125 VDC / Inductive load: 0.05 A(NC) 0.05 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
- Ratings (DC): Non-Inductive load
- Rated voltage: 14 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
- Rated voltage: 125 VDC / Resistive load: 0.5 A(NC) 0.5 A(NO) / Lamp load: 0.4 A(NC) 0.4 A(NO)
- Rated voltage: 250 VDC / Resistive load: 0.25 A(NC) 0.25 A(NO) / Lamp load: 0.2 A(NC) 0.2 A(NO)
- Rated voltage: 8 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
- Rated voltage: 30 VDC / Resistive load: 6 A(NC) 6 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
- Release Force (RF)
- Standard value Min. 0.39 N
- Service life
- General type
- Shape/Structure
- Enclosed Limit switches
- Shock resistance (Destruction)
- 1,000 m/s2
- Shock resistance (Malfunction)
- Contact opening is 1 ms Max. at the free position and the total travel position at 100 m/s2.
- Switching mechanism
- Self-reset mechanism
- Vibration resistance (Malfunction)
- Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position.
- Weight
- 88g