Ratings / Performance
- Actuator
- 17.5 dia. * 7 Sintered stainless steel roller 38 R
- Roller lever
- Ambient humidity
- Operating: 35 to 95%
- Ambient temperature
- Operating: -10 to 70 °C
- Cable specifications
- Diameter: 7.6 mm
- VCTF oil-resistant cable 4 cores (Cable length: 3 m)
- Contact configuration
- Single-Pole, Double-Throw type
- Contact form
- SPDT
- Contact resistance
- 300 mOhm Max. (Initial value) * Including the resistance of cable.
- (Measuring method is contact resistance meter.)
- Degree of protection
- IEC60529 (JEM): IP67
- IEC60529 (JEM): IP67
- Dielectric strength
- Between each terminal of the same polarities: 1000 V
- Between each terminal and non-live-metallic part: 1500 V
- (50/60 Hz for 1 min Without LED)
- Between live-metallic part and ground: 1500 V
- Durability (Electrically)
- 200,000 operations Min. (Resistive load 5 A at 125 VAC)
- (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)
- Durability (Mechanically)
- (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)
- 10,000,000 operations Min. (No load)
- Earth terminal
- With ground terminal
- Electrical ratings
- 5 A at 125 VAC
- Frequency
- 50/60 Hz
- Indicator
- Voltage: 125 VAC
- Leakage current: Approx. 1.7 mA
- LED (Light when not operating)
- Inrush current
- NC: 20 A
- NO: 10 A
- Insulation resistance
- Between each terminal of the same polarities: 100 MΩ
- Between each terminal and non-live-metallic part: 100 MΩ
- (at 500 VDC Megger Without LED)
- Between live-metallic part and ground: 100 MΩ
- Leakage current
- Approx. 1.7 mA
- Load
- General load
- Mounting specification
- Front mounting
- Front mounting
- Movement Differential (MD)
- Standard value 3 DEG Max.
- Standard value 3 DEG Max.
- Operating Force (OF)
- Standard value Max. 5.69 N
- Standard value Max. 5.69 N
- Operating mechanism
- Snap action
- Over-Travel (OT)
- Standard value 40 DEG Min.
- Standard value 40 DEG Min.
- Permissible operating frequency (Electrically)
- 30 operations / 1 minute Max.
- Permissible operating frequency (Mechanically)
- 120 operations / 1 minute Max.
- Permissible operating speed
- 1 mm/s to m/s
- Pollution degree
- 3 (EN60947-5-1)
- Pre-Travel (PT)
- Standard value 25 DEG Max.
- Standard value 25 DEG Max.
- Protective circuit
- Short-circuit protective device: 10 A fuse type gI or gG (IEC269)
- Classification of protection against electric shock: Class I (with ground terminal)
- Ratings (AC): Inductive load
- Rated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
- Ratings (AC): Non-Inductive load
- Rated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
- Release Force (RF)
- Standard value Min. 1.47 N
- Standard value Min. 1.47 N
- Service life
- General type
- Shape/Structure
- General-purpose Limit switches
- Shock resistance (Destruction)
- 1,000 m/s2
- Shock resistance (Malfunction)
- Contact opening is 1 ms Max. at the free position and the total travel position at 500 m/s2.
- Contact opening is 1 ms Max. at the free position and the total travel position at 500 m/s2.
- Switching mechanism
- Self-reset mechanism
- Vibration resistance (Malfunction)
- Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position.