OMRON D4C-1302
Description
OMRON D4C-1302 is now available new, surplus, and used from Williams Automation.
If you need a specific firmware or series relating to this item, please call or email us with your request.
We can also provide specifications and/or a data sheet for this item upon request. Please call or email us if you require one.
Please note we offer UPS Next Day Air shipping for all orders. Please be sure to select next day shipping at checkout, and we will provide same-day shipment.
Call (803) 761-7027 if you have any questions about availability, or email us at sales@williamsautomation.com.
Ratings / Performance
- Actuator
- 12 dia. * 5 Sintered stainless steel roller
- Roller plunger
- Ambient humidity
- Operating: 35 to 95%
- Ambient temperature
- Operating: -10 to 70 °C
- Cable specifications
- Diameter: 7.6 mm
- VCTF oil-resistant cable 4 cores (Cable length: 5 m)
- Contact configuration
- Single-Pole, Double-Throw type
- Contact form
- SPDT
- Contact resistance
- (Measuring method is contact resistance meter.)
- 400 mOhm Max. (Initial value) * Including the resistance of cable.
- Degree of protection
- IEC60529 (JEM): IP67
- Dielectric strength
- Between live-metallic part and ground: 1500 V
- (50/60 Hz for 1 min)
- Between each terminal of the same polarities: 1000 V
- Between each terminal and non-live-metallic part: 1500 V
- Durability (Electrically)
- (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)
- 200,000 operations Min. (Resistive load 5 A at 125 VAC)
- Durability (Mechanically)
- (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)
- 10,000,000 operations Min. (No load)
- Earth terminal
- With ground terminal
- Electrical ratings
- 4 A at 30 VDC
- 5 A at 250 VAC
- Frequency
- 50/60 Hz
- Inrush current
- NO: 10 A
- NC: 20 A
- Insulation resistance
- Between live-metallic part and ground: 100 MΩ
- (at 500 VDC Megger)
- Between each terminal and non-live-metallic part: 100 MΩ
- Between each terminal of the same polarities: 100 MΩ
- Load
- General load
- Mounting specification
- Front mounting
- Movement Differential (MD)
- Standard value 0.2 mm Max.
- Operating Force (OF)
- Standard value Max. 11.77 N
- Operating mechanism
- Snap action
- Operating Position (OP)
- Standard value 28.5 +/- 1 mm
- Over-Travel (OT)
- Standard value 3 mm Min.
- Permissible operating frequency (Electrically)
- 30 operations / 1 minute Max.
- Permissible operating frequency (Mechanically)
- 120 operations / 1 minute Max.
- Permissible operating speed
- 0.1 mm/s to 0.5 m/s
- Pollution degree
- 3 (EN60947-5-1)
- Pre-Travel (PT)
- Standard value 1.8 mm Max.
- Protective circuit
- Short-circuit protective device: 10 A fuse type gI or gG (IEC269)
- Classification of protection against electric shock: Class I (with ground terminal)
- Ratings (AC): Inductive load
- Rated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
- Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)
- Ratings (AC): Non-Inductive load
- Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)
- Rated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
- Ratings (DC): Inductive load
- Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
- Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
- Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
- Rated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
- Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)
- Ratings (DC): Non-Inductive load
- Rated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
- Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
- Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)
- Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
- Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
- Release Force (RF)
- Standard value Min. 4.41 N
- Service life
- General type
- Shape/Structure
- General-purpose Limit switches
- Shock resistance (Destruction)
- 1,000 m/s2
- Shock resistance (Malfunction)
- Contact opening is 1 ms Max. at the free position and the total travel position at 500 m/s2.
- Switching mechanism
- Self-reset mechanism
- Vibration resistance (Malfunction)
- Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position.