OMRON D4C-1220-P
Description
OMRON D4C-1220-P is now available new, surplus, and used from Williams Automation.
If you need a specific firmware or series relating to this item, please call or email us with your request.
We can also provide specifications and/or a data sheet for this item upon request. Please call or email us if you require one.
Please note we offer UPS Next Day Air shipping for all orders. Please be sure to select next day shipping at checkout, and we will provide same-day shipment.
Call (803) 761-7027 if you have any questions about availability, or email us at sales@williamsautomation.com.
Ratings / Performance
- Actuator
- Roller lever
- 17.5 dia. * 7 Sintered stainless steel roller 38 R
- Ambient humidity
- Operating: 35 to 95%
- Ambient temperature
- Operating: -20 to 70 °C
- Cable specifications
- VCTF oil-resistant cable 4 cores (Cable length: 3 m)
- Diameter: 7.6 mm
- Contact configuration
- Single-Pole, Double-Throw type
- Contact form
- SPDT
- Contact resistance
- 300 mOhm Max. (Initial value) * Including the resistance of cable.
- (Measuring method is contact resistance meter.)
- Degree of protection
- IEC60529 (JEM): IP67
- Weather-proof type
- Dielectric strength
- Between each terminal of the same polarities: 1000 V
- Between live-metallic part and ground: 1500 V
- (50/60 Hz for 1 min)
- Between each terminal and non-live-metallic part: 1500 V
- Durability (Electrically)
- 500,000 operations Min. (Resistive load 1 A at 125 VAC)
- (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)
- Durability (Mechanically)
- 500,000 operations Min. (No load)
- (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)
- Electrical ratings
- 5 A at 250 VAC
- 4 A at 30 VDC
- Frequency
- 50/60 Hz
- Inrush current
- NO: 10 A
- NC: 20 A
- Insulation resistance
- (at 500 VDC Megger)
- Between each terminal of the same polarities: 100 MΩ
- Between live-metallic part and ground: 100 MΩ
- Between each terminal and non-live-metallic part: 100 MΩ
- Load
- General load
- Mounting specification
- Front mounting
- Movement Differential (MD)
- Standard value 3 DEG Max.
- Operating Force (OF)
- Standard value Max. 5.69 N
- Operating mechanism
- Snap action
- Over-Travel (OT)
- Standard value 40 DEG Min.
- Permissible operating frequency (Electrically)
- 30 operations / 1 minute Max.
- Permissible operating frequency (Mechanically)
- 120 operations / 1 minute Max.
- Permissible operating speed
- 1 mm/s to m/s
- Pre-Travel (PT)
- Standard value 25 DEG Max.
- Ratings (AC): Inductive load
- Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)
- Rated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
- Ratings (AC): Non-Inductive load
- Rated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
- Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)
- Ratings (DC): Inductive load
- Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
- Rated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
- Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
- Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)
- Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
- Ratings (DC): Non-Inductive load
- Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
- Rated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
- Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
- Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
- Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)
- Release Force (RF)
- Standard value Min. 1.47 N
- Service life
- General type
- Shape/Structure
- General-purpose Limit switches
- Shock resistance (Destruction)
- 1,000 m/s2
- Shock resistance (Malfunction)
- Contact opening is 1 ms Max. at the free position and the total travel position at 500 m/s2.
- Switching mechanism
- Self-reset mechanism
- Vibration resistance (Malfunction)
- Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position.