Classifications
- eClass
- V11.0 : 27370907
- ETIM 9
- EC000640 - Soft starter
- Object Classification Code
- Q
Dimensions
- Product Net Depth / Length
- 196 mm
- Product Net Height
- 260 mm
- Product Net Weight
- 4.8 kg
- Product Net Width
- 160 mm
Environmental
- Ambient Air Temperature
- Operation 0 ... +50 °CStorage -25 ... +70 °C
- Degree of Protection
- IP10
- RoHS Status
- No declaration needed
Ordering
- Customs Tariff Number
- 8503009999
- Minimum Order Quantity
- 1 piece
Technical
- Adjustable Rated Motor Current Ie
- 30 ... 115 %
- Analog Outputs
- 0…10 volts0…20 mA4…20 mA
- By-pass Signal Relay
- Yes
- Communication
- FiledBusPlug(Standard)
- Connecting Capacity Control Circuit
- Rigid 1 x 2.5 mm²Rigid 2 x 1.5 mm²
- Connecting Capacity Main Circuit
- Rigid 1 x 10 ... 95 mm²Rigid 2 x 6 ... 35 mm²
- Connecting Capacity Supply Circuit
- Rigid 1 x 2.5 mm²
- Current Limit Function
- 1.5 ... 7xIe
- Degree of Protection
- IP10
- Fault Signal Relay
- Yes
- Initial Voltage During Start
- 30 ... 70 %
- Integrated Electronic Overload
- Yes
- Number of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time
- 30
- Overload Protection
- Build-in electronic overload protection
- Overload Signal Relay
- Yes
- Product Main Type
- PST37
- Ramp Time
- 0 ... 120 second [unit of time]1 ... 120 second [unit of time]
- Rated Control Circuit Voltage (Uc)
- DC Operation 24 V
- Rated Control Supply Voltage (Us)
- 100 ... 250 V AC
- Rated Frequency (f)
- 50/60 HzMain Circuit 50 / 60 Hz
- Rated Operational Current - In-Line Connection (Ie)
- 37 A
- Rated Operational Current - Inside Delta Connection
- 64 A
- Rated Operational Power - In-Line Connection (Pe)
- (400 V) 18.5 kW(500 V) 22 kW
- Rated Operational Power - Inside Delta Connection
- at 400 V 30 kWat 500 V 37 kW
- Rated Operational Voltage
- Main Circuit 208 ... 600 V AC
- Run Signal Relay
- Yes
- Service Factor Percentage
- 115 %
- Signal Indication Fault (LED)
- Red
- Signal Indication Protection (LED)
- Yellow
- Signal Indication Ready to Start/Standby ON (LED)
- Green
- Starting Capacity at Maximum Rated Current Ie
- 3xIe for 15s
- Step Down Voltage Special Ramp
- 100 ... 30 %
- Switch for Inside Delta Connection
- Yes
- Terminal Type
- Screw Terminals
- Tightening Torque
- Control Circuit 0.5 N·mMain Circuit 6 N·mSupply Circuit 0.5 N·m