Description
ABB 1SBL347001R4100 is now available from Williams Automation.
If you need a specific firmware version or series for this item, please call or email us with your request. We can also provide specifications and/or a data sheet for this item upon request. Please call or email us if you need one.
We offer Overnight shipping for most items listed on our website. Please get in touch with us to confirm whether the product can ship overnight on the day of your order. Cutoff times are typically 2-3 PM EST. Lead times can range from 1 to 4 business days.
Call (803) 761-7027 if you have any questions about availability, or email us at sales@williamsautomation.com.
Classifications
- eClass
- V11.0 : 27371003
- E-Number (Finland)
- 3706596
- ETIM 4
- EC000066 - Magnet contactor, AC-switching
- ETIM 5
- EC000066 - Magnet contactor, AC-switching
- IDEA Granular Category Code (IGCC)
- 4758 >> Iec Contactors
- Object Classification Code
- Q
Dimensions
- Product Net Depth / Length
- 111 mm
- Product Net Height
- 125.5 mm
- Product Net Weight
- 0.97 kg
- Product Net Width
- 55 mm
Environmental
- Ambient Air Temperature
- Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °CClose to Contactor without Thermal O/L Relay -40 ... 70 °CClose to Contactor for Storage -60 ... +80 °C
- Climatic Withstand
- Category B according to IEC 60947-1 Annex Q
- Maximum Operating Altitude Permissible
- Without Derating 3000 m
- Resistance to Shock acc. to IEC 60068-2-27
- Closed, Shock Direction: A 25 gClosed, Shock Direction: B1 25 gClosed, Shock Direction: B2 15 gClosed, Shock Direction: C1 25 gClosed, Shock Direction: C2 25 gOpen, Shock Direction: B1 5 g
- Resistance to Vibrations acc. to IEC 60068-2-6
- 5 ... 300 Hz 3 g closed position / 3 g open position
- RoHS Status
- Following EU Directive 2011/65/EU
Ordering
- Customs Tariff Number
- 85364900
- Minimum Order Quantity
- 1 piece
Technical
- Connecting Capacity Control Circuit
- Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid Solid 1/2x 1 ... 2.5 mm²Rigid Stranded 1/2x 1 ... 2.5 mm²
- Connecting Capacity Main Circuit
- Flexible with Ferrule 1/2x 4 ... 35 mm²Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²Rigid Stranded 1/2x 6 ... 35 mm²
- Conventional Free-air Thermal Current (Ith)
- acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
- Degree of Protection
- acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
- Maximum Breaking Capacity
- cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
- Maximum Electrical Switching Frequency
- (AC-1) 600 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 1200 cycles per hour
- Maximum Mechanical Switching Frequency
- 3600 cycles per hour
- Mounting by Screws (not supplied)
- 2 x M4 or 2 x M6 screws placed diagonally
- Mounting on DIN Rail
- TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
- Number of Auxiliary Contacts NC
- 0
- Number of Auxiliary Contacts NO
- 0
- Number of Main Contacts NC
- 0
- Number of Main Contacts NO
- 3
- Operate Time
- Between Coil De-energization and NC Contact Closing 19 ... 105 msBetween Coil De-energization and NO Contact Opening 17 ... 100 msBetween Coil Energization and NC Contact Opening 38 ... 95 msBetween Coil Energization and NO Contact Closing 42 ... 100 ms
- Rated Control Circuit Voltage (Uc)
- 50 Hz 24 ... 60 V60 Hz 24 ... 60 VDC Operation -
- Rated Frequency (f)
- Control Circuit 50 / 60 HzMain Circuit 50 / 60 Hz
- Rated Impulse Withstand Voltage (Uimp)
- 6 kV
- Rated Insulation Voltage (Ui)
- acc. to IEC 60947-4-1 690 Vacc. to UL/CSA 600 V
- Rated Operational Current AC-1 (Ie)
- (690 V) 40 °C 70 A(690 V) 60 °C 60 A(690 V) 70 °C 50 A
- Rated Operational Current AC-3e (Ie)
- (415 V) 60 °C 40 A(440 V) 60 °C 40 A(500 V) 60 °C 35 A(690 V) 60 °C 25 A(380 / 400 V) 60 °C 40 A(220 / 230 / 240 V) 60 °C 40 A
- Rated Operational Current AC-3 (Ie)
- (415 V) 60 °C 40 A(440 V) 60 °C 40 A(500 V) 60 °C 35 A(690 V) 60 °C 25 A(380 / 400 V) 60 °C 40 A(220 / 230 / 240 V) 60 °C 40 A
- Rated Operational Current DC-1 (Ie)
- (110 V) 2 Poles in Series, 40 °C 70 A(110 V) 2 Poles in Series, 60 °C 60 A(110 V) 2 Poles in Series, 70 °C 50 A(110 V) 3 Poles in Series, 40 °C 70 A(110 V) 3 Poles in Series, 60 °C 60 A(110 V) 3 Poles in Series, 70 °C 50 A(220 V) 3 Poles in Series, 40 °C 70 A(220 V) 3 Poles in Series, 60 °C 60 A(220 V) 3 Poles in Series, 70 °C 50 A(72 V) 1-Pole, 40 °C 70 A(72 V) 1-Pole, 60 °C 60 A(72 V) 1-Pole, 70 °C 50 A(72 V) 2 Poles in Series, 40 °C 70 A(72 V) 2 Poles in Series, 60 °C 60 A(72 V) 2 Poles in Series, 70 °C 50 A(72 V) 3 Poles in Series, 40 °C 70 A(72 V) 3 Poles in Series, 60 °C 60 A(72 V) 3 Poles in Series, 70 °C 50 A
- Rated Operational Current DC-3 (Ie)
- (110 V) 2 Poles in Series, 40 °C 70 A(110 V) 2 Poles in Series, 60 °C 60 A(110 V) 2 Poles in Series, 70 °C 50 A(110 V) 3 Poles in Series, 40 °C 70 A(110 V) 3 Poles in Series, 60 °C 60 A(110 V) 3 Poles in Series, 70 °C 50 A(220 V) 3 Poles in Series, 40 °C 70 A(220 V) 3 Poles in Series, 60 °C 60 A(220 V) 3 Poles in Series, 70 °C 50 A(72 V) 1-Pole, 40 °C 70 A(72 V) 1-Pole, 60 °C 60 A(72 V) 1-Pole, 70 °C 50 A(72 V) 2 Poles in Series, 40 °C 70 A(72 V) 2 Poles in Series, 60 °C 60 A(72 V) 2 Poles in Series, 70 °C 50 A(72 V) 3 Poles in Series, 40 °C 70 A(72 V) 3 Poles in Series, 60 °C 60 A(72 V) 3 Poles in Series, 70 °C 50 A
- Rated Operational Current DC-5 (Ie)
- (110 V) 2 Poles in Series, 40 °C 70 A(110 V) 2 Poles in Series, 60 °C 60 A(110 V) 2 Poles in Series, 70 °C 50 A(110 V) 3 Poles in Series, 40 °C 70 A(110 V) 3 Poles in Series, 60 °C 60 A(110 V) 3 Poles in Series, 70 °C 50 A(220 V) 3 Poles in Series, 40 °C 70 A(220 V) 3 Poles in Series, 60 °C 60 A(220 V) 3 Poles in Series, 70 °C 50 A(72 V) 1-Pole, 40 °C 70 A(72 V) 1-Pole, 60 °C 60 A(72 V) 1-Pole, 70 °C 50 A(72 V) 2 Poles in Series, 40 °C 70 A(72 V) 2 Poles in Series, 60 °C 60 A(72 V) 2 Poles in Series, 70 °C 50 A(72 V) 3 Poles in Series, 40 °C 70 A(72 V) 3 Poles in Series, 60 °C 60 A(72 V) 3 Poles in Series, 70 °C 50 A
- Rated Operational Power AC-3e (Pe)
- (415 V) 22 kW(440 V) 22 kW(500 V) 22 kW(690 V) 22 kW(380 / 400 V) 18.5 kW(220 / 230 / 240 V) 11 kW
- Rated Operational Power AC-3 (Pe)
- (400 V) 18.5 kW(415 V) 22 kW(440 V) 22 kW(500 V) 22 kW(690 V) 22 kW(380 / 400 V) 18.5 kW(220 / 230 / 240 V) 11 kW
- Rated Operational Voltage
- Main Circuit 690 V
- Rated Short-time Withstand Current Low Voltage (Icw)
- at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
- Standards
- IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
- Terminal Type
- Screw Terminals
- Wire Stripping Length
- Control Circuit 10 mmMain Circuit 16 mm
Technical UL/CSA
- Connecting Capacity Control Circuit UL/CSA
- Rigid Solid 1/2x 18-14 AWGRigid Stranded 1/2x 18-14 AWG
- Connecting Capacity Main Circuit UL/CSA
- Rigid Stranded 1/2x 10-2 AWG
- Continuous Current Rating NEMA
- 45 A
- General Use Rating UL/CSA
- (600 V AC) 60 A
- Horsepower Rating NEMA
- (115 V AC) Single Phase 3 Hp(200 V AC) Three Phase 10 Hp(230 V AC) Single Phase 7-1/2 Hp(230 V AC) Three Phase 15 Hp(460 V AC) Three Phase 25 Hp(575 V AC) Three Phase 25 Hp
- Horsepower Rating UL/CSA
- (120 V AC) Single Phase 3 hp(200 ... 208 V AC) Three Phase 10 hp(220 ... 240 V AC) Three Phase 15 hp(240 V AC) Single Phase 7-1/2 hp(440 ... 480 V AC) Three Phase 30 hp(550 ... 600 V AC) Three Phase 40 hp
- NEMA Size
- 2
- Tightening Torque UL/CSA
- Control Circuit 11 in·lbMain Circuit 35 in·lb