Description
SmartOnline 120V 1kVA 800W Double-Conversion UPS, Tower, Extended Run, Network Card Options, USB, DB9 Serial
Tripp Lite SU1000XLA is now available new, surplus, and used from Williams Automation.
If you need a specific firmware or series relating to this item, please call or email us with your request.
We can also provide specifications and/or a data sheet for this item upon request. Please call or email us if you require one.
Please note we offer UPS Next Day Air shipping for all orders. Please be sure to select next day shipping at checkout, and we will provide same-day shipment.
Call (803) 761-7027 if you have any questions about availability, or email us at sales@williamsautomation.com.
Battery
- Battery Access
- Battery access door
- Battery Recharge Rate (Included Batteries)
- Less than 6 hours from 10% to 90% (typical, full load discharge)
- Battery Replacement Description
- Hot-swappable, user replaceable batteries
- DC System Voltage (VDC)
- 24
- Expandable Battery Runtime
- Extended runtime supported via optional external battery packs
- Expandable Runtime
- Yes
- External Battery Pack Compatibility
- BP24V15RT2U (limit 1); BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible)
- Full Load Runtime (min.)
- 4.5 min. (800w)
- Half Load Runtime (min.)
- 14 min. (400w)
- Internal UPS Replacement Battery Cartridge
- RBC24-SUTWR
Certifications
- UPS Certifications
- Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category B (EMI)
Communications
- Communications Cable
- USB and DB9 cabling included
- Communications Interface
- USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface
- Network Management Cards
- SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD
- Network Monitoring Port Description
- Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications; Economy-mode setting option is available using PowerAlert software and DB9 Serial cable connection OR via select Network Management Card options
- PowerAlert Software
- For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
- WatchDog Compatibility
- Supports Watchdog application, OS and hard-reboot restart options for remote applications
Environmental
- AC Economy Mode BTU / Hr. (Full Load)
- 84
- AC Economy Mode Efficiency Rating (100% Load)
- 97%
- AC Mode BTU / Hr. (Full Load)
- 408
- AC Mode Efficiency Rating (100% Load)
- 87%
- Audible Noise
- < 45 dB at front side 1m
- Operating Temperature Range
- +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
- Relative Humidity
- 0 to 95%, non-condensing
- Storage Temperature Range
- +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Input
- Input Circuit Breakers
- 15A
- Input Phase
- Single-Phase
- Nominal Input Voltage(s) Supported
- 100V AC; 110V AC; 120V AC
- Rated input current (Maximum Load)
- 8.6A
- Recommended Electrical Service
- 15A 120V
- UPS Input Connection Type
- 5-15P
- UPS Input Cord Length (ft.)
- 10
Line / Battery Transfer
- High Voltage Transfer to Battery Power (Setpoint)
- 150
- Low Voltage Transfer to Battery Power (Setpoint)
- 80V (100% load), 65V ( <70% load)
- Transfer Time
- No transfer time (0 ms.) in online, double-conversion mode
Output
- Crest Factor
- 3:1
- Frequency Compatibility
- 50 / 60 Hz
- Frequency Compatibility Details
- Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start
- Individually Controllable Load Banks
- Yes
- Load Management Receptacles
- Two switchable single-outlet 5-15R load banks
- Nominal Output Voltage(s) Supported
- 100V; 110V; 120V
- Nominal Voltage Details
- 120V default
- Output AC Waveform (AC Mode)
- Sine wave
- Output AC Waveform (Battery Mode)
- Pure Sine wave
- Output Capacity Details
- OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)
- Output kVA Capacity (kVA)
- 1
- Output Receptacles
- (6) 5-15R
- Output Voltage Regulation (Battery Mode)
- +/- 2%
- Output Voltage Regulation (Economy Line Mode)
- +/- 10%
- Output Voltage Regulation (Line Mode)
- +/- 2%
- Output Volt Amp Capacity (VA)
- 1000
- Output Watt Capacity (Watts)
- 800
- Power Factor
- 0.8
Overview
- UPC Code
- 037332126559
- UPS Type
- On-Line
Physical
- Cooling Method
- Fan
- Primary Form Factor
- Tower
- Primary UPS Depth (mm)
- 335
- Primary UPS Height (mm)
- 254
- Primary UPS Width (mm)
- 173
- Shipping Dimensions (hwd / in.)
- 13.90 x 9.70 x 17.90
- Shipping Weight (lbs.)
- 33.30
- UPS Housing Material
- Steel
- UPS Power Module Dimensions (hwd, in.)
- 10 x 6.8 x 13.2
- UPS Power Module Weight (kg)
- 13.52
- UPS Power Module Weight (lbs.)
- 29.8
Special Features
- Cold Start (Startup in Battery Mode During a Power Failure)
- Cold-start operation supported
- Green Energy-Saving Features
- High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy mode operation
- High Availability UPS Features
- Automatic inverter bypass; Hot swappable batteries
Surge / Noise Suppression
- EMI / RFI AC Noise Suppression
- Yes
- UPS AC Suppression Joule Rating
- 570
- UPS AC Suppression Response Time
- Instantaneous
- UPS Dataline Suppression
- 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
User Interface, Alerts & Controls
- Audible Alarm
- Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
- LED Indicators
- 14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information - includes 4-LED meter display for load and battery charge level
- Switches
- 2 switches control off/on power status and alarm-cancel/self-test operation
Voltage Regulation
- Overvoltage Correction
- 2% output voltage regulation during overvoltages to 150
- Severe Undervoltage Correction
- 2% output voltage regulation during undervoltages to 65 (under 70% load only)
- Undervoltage Correction
- 2% output voltage regulation during undervoltages to 80
- Voltage Regulation Description
- Online, double-conversion power conditioning
Warranty
- Connected Equipment Insurance (U.S., Canada & Puerto Rico)
- $250,000 Ultimate Lifetime Insurance
- Product Warranty Period (Worldwide)
- 2-year limited warranty
Reviews
What our customers say
BBB 4.7
Rating
they have quick great service and quick shipping!! would recommend doing business over and over!!
Great price and speedy delivery. I am certain, based on my first statement that if needed, customer support will be excellent
Great customer service, fast shipping. Nice to deal with a company that shows they care about their customers.
I got the part and it was exactly what i needed to get my dust collector up and running again! It was also at very reasonable price. Thanks!
Another great purchase from Williams Automation. You will have peace of mind knowing your getting authentic parts from Williams Automation. Very easy to work with and great customer service. Plus you get at a competitive price and not three times what it should be.
Exceptional customer service! They had the elusive part I required readily available and responded promptly to all my emails.
Great customer service. Had the hard to find parts I needed in stock. All emails answered promptly.
Had what I needed in stock, shipped fast and arrived within the time frame indicated. It was packaged securely.
Perfect purchase! The whole process was great, including the packaging and shipping. Finally a company who cares!
Great service and Best prices ! Very organized company and helpful too. Will definitely buy again