Schrack 9-1415053-1





Description
Schrack 9-1415053-1 is now available new, surplus, and used from Williams Automation.
If you need a specific firmware or series relating to this item, please call or email us with your request.
We can also provide specifications and/or a data sheet for this item upon request. Please call or email us if you require one.
Please note we offer UPS Next Day Air shipping for all orders. Please be sure to select next day shipping at checkout, and we will provide same-day shipment.
Call (803) 761-7027 if you have any questions about availability, or email us at sales@williamsautomation.com.
Body Features
- Product Weight
- 30 g
- 1.058 oz
Contact Features
- Contact Arrangement
- 3 Form A (NO) + 1 Form B (NC)
- Contact Current Class
- 5 – 10 A
- Contact Current Rating (Max)
- 8 A
- Contact Material
- AgSnO2
- Contact Number of Poles
- 4
- Contact Special Features
- Force Guided Contacts
- Terminal Type
- PCB-THT
Dimensions
- Height Class (Mechanical)
- 16 – 20 mm
- Insulation Clearance Between Contact & Coil
- .394 in
- 10 mm
- Insulation Clearance Class
- 8 mm
- Length Class (Mechanical)
- 35 – 40 mm
- Product Height
- 16.5 mm
- .65 in
- Product Length
- 40 mm
- 1.575 in
- Product Width
- 13 mm
- .512 in
- Width Class (Mechanical)
- 12 – 16 mm
Electrical Characteristics
- Coil Current
- 44.444 A
- Coil Magnetic System
- Monostable, DC
- Coil Power Rating Class
- 600 – 800 mW
- Coil Power Rating DC
- 800 mW
- Coil Resistance
- 405 Ω
- Coil Voltage Rating
- 18 VDC
- Contact Limiting Breaking Current
- 8 A
- Contact Limiting Continuous Current
- 8 A
- Contact Limiting Making Current
- 8 A
- Contact Limiting Short-Time Current
- 8 A
- Contact Switching Load (Min)
- 10mA @ 5V
- Contact Switching Voltage (Max)
- 400 VAC
- Contact Voltage Rating
- 250 VAC
- Insulation Creepage Between Contact & Coil
- 10 mm
- .394 in
- Insulation Creepage Class
- 8 mm
- Insulation Initial Dielectric Between Adjacent Contacts
- 2500 Vrms
- Insulation Initial Dielectric Between Coil & Contact Class
- 3500 – 4000 V
- Insulation Initial Dielectric Between Contacts & Coil
- 4000 Vrms
- Insulation Initial Dielectric Between Open Contacts
- 1500 Vrms
Mechanical Attachment
- Relay Mounting Type
- Printed Circuit Board
Other
- Comment
- Well suited for emergency shut-off, machine control, elevator and escalator control, light barrier control
Packaging Features
- Packaging Method
- Box & Tube
- Tube
Product Type Features
- Power Relay Type
- Force-Guided
Usage Conditions
- Environmental Ambient Temperature Class
- -25 – 70 °C
- Environmental Ambient Temperature (Max)
- 158 °F
- 70 °C
- Environmental Category of Protection
- RTIII
Williams Automation sells Schrack parts at huge savings. Search to find the part you need today. If you can't find what you are looking for please Request A Quote from us and we will provide a timely response. You can also call us at 803-761-7027. We look forward to working with you to assist in the best way we can for your industrial needs.
Reviews
What our customers say