Complementary
- Backup Time
- 10 years 25 °C
- Checks
- program memory on each power up
- Clock
- with
- Clock Drift
- 12 min/year 0-55 °C || 6 s/month 25-25 °C
- Connections - Terminals
- screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) semi-solid || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) solid || screw terminals, 1 x 0.25...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) solid || screw terminals, 2 x 0.25...2 x 0.75 mm² AWG 24...AWG 18) flexible with cable end
- Contacts Type And Composition
- NO relay output
- Current State 0 Guaranteed
- <= 0.5 mA discrete input)
- Current State 1 Guaranteed
- >= 0.17 mA discrete input)
- Cycle Time
- 6-90 ms
- Discrete Input Current
- 0.6 mA
- Discrete Input Frequency
- 47...53 Hz || 57...63 Hz
- Discrete Input Number
- 16
- Discrete Input Voltage
- 100...240 V AC
- Electrical Durability
- AC-12 500000 cycles 230 V, 1.5 A relay output EN/IEC 60947-5-1 || AC-15 500000 cycles 230 V, 0.9 A relay output EN/IEC 60947-5-1 || DC-12 500000 cycles 24 V, 1.5 A relay output EN/IEC 60947-5-1 || DC-13 500000 cycles 24 V, 0.6 A relay output EN/IEC 60947-5-1
- Input Impedance
- 350 kOhm discrete input
- Isolation Voltage
- 1780 V
- Local Display
- with
- Maximum Supply Current
- 100 mA 100 V without extension) || 50 mA 240 V without extension) || 60 mA 240 V with extensions) || 80 mA 100 V with extensions)
- Mechanical Durability
- 10000000 cycles relay output
- Net Weight
- 0.4 kg
- Number Of Outputs
- 10 relay
- Number Or Control Scheme Lines
- 0-500 FBD || 0-240 ladder
- Operating Rate In Hz
- 0.1 Hz at Ie)relay output || 10 Hz no load)relay output
- Output Thermal Current
- 5 A for 2 outputs relay output || 8 A for 8 outputs relay output
- Output Voltage Limits
- 5...30 V DC relay output) || 24...250 V AC
- Overvoltage Category
- III EN/IEC 60664-1
- Power Consumption In Va
- 12 VA without extension || 17 VA with extensions
- Protection Type
- against inversion of terminals (control instructions not executed)
- Response Time
- 50 ms ladder from state 0 to state 1)discrete input || 50 ms ladder from state 1 to state 0)discrete input || 50...255 ms FBD from state 0 to state 1)discrete input || 50...255 ms FBD from state 1 to state 0)discrete input || 10 ms from state 0 to state 1)relay output || 5 ms from state 1 to state 0)relay output
- Supply Frequency
- 50/60 Hz
- Supply Voltage Limits
- 85-264 V
- Switching Capacity In Ma
- >= 10 mA 12 V relay output)
- Tightening Torque
- 0.5 N.m
- [Uimp] Rated Impulse Withstand Voltage
- 4 kV EN/IEC 60947-1 and EN/IEC 60664-1
- [Us] Rated Supply Voltage
- 100...240 V
- Voltage State 0 Guaranteed
- <= 40 V discrete input
- Voltage State 1 Guaranteed
- >= 79 V discrete input
Contractual warranty
- Warranty
- 18 months
Environment
- Ambient Air Temperature For Operation
- -20-40 °C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2 || -20-55 °C IEC 60068-2-1 and IEC 60068-2-2
- Ambient Air Temperature For Storage
- -40-70 °C
- Disturbance Radiated/Conducted
- class B EN 55022-11 group 1
- Environmental Characteristic
- EMC directive EN/IEC 61000-6-2 || EMC directive EN/IEC 61000-6-3 || EMC directive EN/IEC 61000-6-4 || EMC directive EN/IEC 61131-2 zone B || low voltage directive EN/IEC 61131-2
- Immunity To Microbreaks
- 10 ms
- Ip Degree Of Protection
- IP20 IEC 60529 terminal block) || IP40 IEC 60529 front panel)
- Maximum Altitude Transport
- 3048 m
- Operating Altitude
- 6561.68 ft (2000 m)
- Pollution Degree
- 2 EN/IEC 61131-2
- Product Certifications
- GOST || GL || CSA || UL || C-tick
- Relative Humidity
- 95-95 % without condensation or dripping water
- Standards
- EN/IEC 61000-4-12 || EN/IEC 60068-2-27 Ea || EN/IEC 60068-2-6 Fc || EN/IEC 61000-4-6 level 3 || EN/IEC 61000-4-5 || EN/IEC 61000-4-11 || EN/IEC 61000-4-3 || EN/IEC 61000-4-2 level 3 || EN/IEC 61000-4-4 level 3
Offer Sustainability
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- China Rohs Regulation
- X
- Circularity Profile
- ENVEOLI0604006EN
- Environmental Disclosure
- ENVPEP060406EN
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
- Mercury Free
- Yes
- Pvc Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- Rohs Exemption Information
- Yes
- Sustainable Offer Status
- Green Premium product
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Specifications
- Product Or Component Type
- modular smart relay
- Range Of Product
- Zelio Logic