Electrical Specifications
- 80 BK Temperature Probe
- –40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater–40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater
- AC Current Amps accuracy
- ±(1.0% + 2) true-rms
- AC Current Maximum resolution
- 0.1 µA
- AC Current Range
- 0.1 μA to 10 A(20 A for 30 seconds maximum)
- AC Voltage/td> AC Bandwidth
- 20 kHz with low pass filter; 3 dB @ 1 kHz
- AC Voltage/td> Accuracy
- ±(0.7% + 4) true-rms
- AC Voltage/td> Maximum Resolution
- 0.1 mV
- AC Voltage/td> Range
- 0.1 mV to 1000 V
- Capacitance Accuracy
- ±(1% + 2)
- Capacitance Maximum resolution
- 0.01 nF
- Capacitance Range
- 0.01 nF to 9999 μF
- Conductance Accuracy
- ±(1.0% + 10)
- Conductance Maximum conductance
- 60.00 nS
- Conductance Maximum Resolution
- 0.01 nS
- DC Current Amps accuracy
- ±(0.2% + 2)
- DC Current Maximum resolution
- 0.01 µA
- DC Current Range
- 0.1 μA to 10 A(20 A for 30 seconds maximum)
- DC Voltage Accuracy
- ±(0.05% + 1)
- DC Voltage Maximum Resolution
- 0.1 mV
- DC Voltage Range
- 0.1 mV to 1000 V
- Diagnostics and data storage
- Peak Min/Max: 250 μS
- Diode test Accuracy
- ±(1% + 1)
- Diode test Range
- 2 V
- Diode test Resolution
- 0.001 V
- Display Analog bar graph
- 32 segments, updates 40/second
- Display Backlight
- two level
- Display Digital
- 6000 counts updates 4/second19,999 counts in high–resolution mode
- Duty Cycle Accuracy
- ±(0.2% per kHz + 0.1%)
- Duty Cycle Maximum duty cycle
- 99.9%
- Duty Cycle Maximum Resolution
- 0.1%
- Frequency Accuracy
- ±(0.005% + 1)
- Frequency Maximum resolution
- 0.01 Hz
- Frequency Range
- 0.5 Hz to 199.99 kHz
- Input AlertTM
- Yes
- Low pass filter(VFD measurements)
- Yes
- Min/Max/Avg
- Yes
- Reading hold/Auto (Touch) Hold
- Yes
- Relative reference
- Yes
- Resistance Accuracy
- ±(0.2% + 1)
- Resistance Maximum resolution
- 0.1Ω
- Resistance Range
- 0.1 Ω to 50 MΩ
- Temperature measurement range
- –200.0 °C to 1090 °C–328.0 °F to 1994.0 °Fexcluding probe
Environmental Specifications
- Humidity (without condensation)
- 0% – 90% (0 °C – 35 °C)0% – 70% (35 °C – 55 °C)
- Operating Altitude
- 2000 m
- Operating temperature
- -15 °C to 55 °C, to -40 °C for 20 minutes when taken from 20 °C
- Storage temperature
- –40 °C to + 60 °C
Mechanical and General Specifications
- IP rating:
- IEC 60529: IP67
- Power
- Three AA batteries. 800 hours typical, without backlight
- Size
- 6.0 x 10.1 x 21.5 cm (with holster)
- Warranty
- Limited lifetime
- Weight
- 698.5 g (with holster)
Safety Specifications
- Agency approvals
- CE, CSA
- Safety rating
- IEC61010-1: Pollution Degree 2IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V